Home / Products / Air Cooled Chillers / 25HP Air Cooled Chiller
Air Cooled Chiller Series • 25HP Large Medium-Duty Range

25HP Air Cooled Chiller for Industrial Process Cooling

APT 25HP air cooled chiller provides large medium-duty process cooling for injection molding, die casting auxiliary cooling, hydraulic systems, extrusion, process tanks, CNC production lines, electroplating, thermal spray auxiliary cooling, and general industrial temperature control. Pump, tank, evaporator, voltage, controller, cabinet layout, and high ambient design can be customized according to project requirements.

Approx. 60-75 kW Cooling Capacity Air Cooled Condenser Large Medium-Duty Process Cooling Custom Pump & Tank Export Voltage Options
25HP air cooled industrial chiller for large medium duty process cooling by APT Industrial Chiller
Quick Answer

When Should You Choose a 25HP Air Cooled Chiller?

A 25HP air cooled chiller is suitable for large medium-duty industrial process cooling where approximately 60-75 kW cooling capacity is required without using a cooling tower. It is commonly selected for injection molding, hydraulic systems, extrusion lines, process tanks, die casting auxiliary cooling, CNC production lines, electroplating, and thermal spray auxiliary cooling. Final configuration should be confirmed according to heat load, water temperature, water flow, pump pressure, ambient temperature, voltage, and installation ventilation.

Approx. 60-75 kW Cooling Capacity

Reviewed for larger medium-duty process loads where 20HP capacity is no longer sufficient.

No Cooling Tower Required

Air cooled installation simplifies workshop planning when condenser water systems are not preferred.

Custom Pump, Tank and Voltage

APT can adjust hydraulic, electrical, and control details according to the actual process loop and export standard.

Product Overview

Large Medium-Duty 25HP Air Cooled Chiller for Industrial Process Cooling

The 25HP air cooled chiller is a practical large medium-duty cooling unit for industrial equipment that requires higher cooling capacity than 20HP models while still benefiting from air cooled installation. With an air cooled condenser, scroll compressor, process water circuit, circulation pump, controller, and optional water tank or evaporator configuration, it can be used as an independent cooling source for production equipment, process tanks, hydraulic systems, extrusion lines, and machine-side cooling loops.

Suitable for large medium-duty process cooling loads
Higher capacity than 20HP models
No cooling tower required
Supports process tank, hydraulic, extrusion and machine-side cooling
Can be customized for pump, tank, evaporator and voltage
Suitable for export projects and different power standards
25HP air cooled industrial chiller application for CNC production line cooling
Key Features

Key Features of the 25HP Air Cooled Industrial Chiller

25HP Cooling Capacity

Approx. 60-75 kW cooling capacity for large medium-duty industrial process cooling.

Air Cooled Condenser

No cooling tower is required, making installation simpler for workshops and equipment-side cooling.

Scroll Compressor

Reliable compressor configuration for stable refrigeration and continuous industrial operation.

Custom Pump and Tank

Pump flow, pump head, tank volume, and water circuit can be configured according to project needs.

Flexible Evaporator Options

Tank coil, shell and tube, plate, or other evaporator directions can be reviewed based on water quality and process loop.

Export Voltage and Control

Voltage, frequency, controller, alarm output, and protection logic can be customized for destination markets.

Application Fit Matrix

Application Fit Matrix

Use this matrix to check whether a 25HP air cooled chiller is suitable for your industrial cooling application.

Application Fit Level Typical Cooling Need Engineering Review
Injection Molding CoolingHighMedium to larger mold cooling, auxiliary cooling, process water temperature controlMold heat load, tank volume, water flow, production duty cycle
Hydraulic System CoolingHighHydraulic oil cooling with heat exchanger or process water loopOil heat load, exchanger type, water flow, pump pressure, material compatibility
Extrusion CoolingMedium to HighExtrusion line cooling, process water loop, production temperature controlHeat load, duty cycle, water flow, tank volume, ambient temperature
CNC Production Line CoolingMedium to HighMultiple machines, cutting fluid tank cooling, machine-side water loopTotal heat load, coolant loop, pump pressure, filtration, temperature stability
Electroplating CoolingMedium to HighPlating bath temperature control and process tank coolingTank volume, chemical compatibility, evaporator material, heat gain
Die Casting Auxiliary CoolingMediumAuxiliary cooling for die casting equipment, molds or hydraulic systemsHeat load, water temperature, pump pressure, duty cycle
Thermal Spray Auxiliary CoolingMediumAuxiliary cooling for process equipment and supporting systemsHeat load, operating schedule, ambient temperature, pump pressure
General Process Tank CoolingMedium to HighProcess water tank or machine-side temperature controlTank size, heat load, insulation, ambient temperature, pump head
Technical Data

Technical Data - 25HP Air Cooled Chiller

The following data is for preliminary reference. Final configuration should be confirmed according to cooling capacity, ambient temperature, water flow, pump head, voltage, evaporator type, and process requirements.

ModelAC-25HP
Cooling CapacityApprox. 60-75 kW / 17-21 RT reference
Compressor Power25 HP
Compressor TypeScroll compressor / project dependent
Cooling MethodAir cooled
CondenserCopper tube aluminum fin air cooled condenser
EvaporatorTank coil / shell and tube / plate / customizable
Temperature Control Range5°C - 35°C
Temperature Accuracy±1°C
RefrigerantR407C / R410A / R134a, project dependent
PumpCustomizable flow and head
Power Supply3PH 380V 50Hz / customizable
ProtectionHigh and low pressure, overload, phase, flow and anti-freeze protection
ControlDigital controller / PLC optional
CabinetStandard or customized industrial cabinet
Selection Matrix

25HP Chiller Selection Matrix

Use this matrix to decide whether a 25HP air cooled chiller is the right starting point or whether a smaller, larger, water cooled, or custom chiller direction should be reviewed.

Cooling Requirement Recommended Direction Best For Engineering Review Next Step
Smaller heat load around 58-60 kW 20HP Air Cooled Chiller Upper medium-duty process cooling, single or multiple machines, moderate duty cycle Heat load, water flow, pump head, installation ventilation View 20HP Chiller Page →
Large medium-duty process cooling around 60-75 kW 25HP Air Cooled Chiller Injection molding, hydraulic systems, extrusion, process tanks, CNC production lines Cooling capacity, water temperature, pump flow, ambient temperature Submit 25HP Requirements →
Higher heat load above approx. 75-90 kW 30HP Air Cooled Chiller Production lines, hydraulic cooling, chemical process loops, higher duty cycles Heat load margin, pump pressure, condenser ventilation, system layout View 30HP Chiller Page →
Poor indoor ventilation or plant cooling water available Water Cooled Industrial Chiller Indoor rooms, larger cooling loops, stable plant water systems Cooling water availability, tower loop, pump pressure, installation layout View Water Cooled Chillers →
Special process, voltage, evaporator, or high ambient condition Custom Industrial Chiller Special fluids, T3 regions, OEM integration, corrosion-resistant requirements Ambient temperature, material compatibility, controls, voltage, cabinet layout View Custom Chillers →
Customization Options

Customizable for Your Cooling Requirement

APT can customize this 25HP air cooled chiller according to the customer's process, installation environment, and destination country power supply.

Pump Flow and Head

Match circulation performance to piping resistance, exchanger layout, and required process flow.

Water Tank Volume

Adjust water reserve based on duty cycle, tank loop size, and process thermal fluctuation.

Evaporator Type

Review tank coil, shell and tube, plate, or special evaporator direction according to the water circuit.

Voltage and Frequency

Support export electrical standards and project-specific power requirements.

Controller and Alarm

Optional PLC, HMI, alarm, and communication integration for equipment-side control logic.

Refrigerant Direction

Select refrigerant according to project region, operating condition, and engineering preference.

Cabinet Layout

Cabinet structure and service access can be adjusted to fit workshop constraints.

High Ambient Design

Condenser margin, protection, and fan design can be reviewed for hot climate operation.

Quote Checklist

Quote Information Checklist

To recommend a suitable 25HP air cooled chiller, please prepare the following cooling requirement information before quotation review.

Application industry or cooling object

Required cooling capacity or heat load

Inlet and outlet water temperature

Water flow rate and pump head

Ambient temperature around the chiller

Power supply voltage and frequency

Installation space and ventilation condition

Water quality and evaporator material requirements

Required tank volume or pump configuration

Control, alarm or communication requirements

Related Products and Resources

Explore Related APT Cooling Solutions

FAQ

FAQ About 25HP Air Cooled Chillers

What applications is a 25HP air cooled chiller suitable for?

It is commonly used for injection molding, hydraulic systems, extrusion lines, CNC production lines, electroplating, die casting auxiliary cooling, thermal spray auxiliary cooling, process tanks, and general industrial process cooling.

What cooling capacity does a 25HP air cooled chiller provide?

A typical 25HP air cooled chiller provides approximately 60-75 kW cooling capacity depending on chilled water temperature, ambient temperature, compressor selection, condenser size, and pump configuration.

Does a 25HP air cooled chiller need a cooling tower?

No. An air cooled chiller rejects heat through its condenser and fan system, so it does not require a cooling tower. Good condenser airflow and installation ventilation are still important.

Can the 25HP chiller be customized for my process?

Yes. APT can customize pump pressure, water tank size, evaporator type, voltage, controller, outlet direction, condenser design, and high ambient configuration based on working conditions.

Can a 25HP chiller be used for hydraulic system cooling?

Yes. A 25HP air cooled chiller can support hydraulic system cooling when used with a suitable heat exchanger or process water loop selected according to oil heat load, flow rate, and temperature requirements.

Is 25HP enough for multiple machines?

It may be suitable for multiple machines or larger process tanks, but the final selection should be based on total heat load, required water flow, operating hours, and heat load margin.

Is air cooled or water cooled better for a 25HP chiller?

Air cooled chillers are easier to install because they do not require a cooling tower. Water cooled models may be preferred when plant water systems are available or when installation space and ambient temperature require a different design.

Can APT customize pump flow and pump head?

Yes. Pump flow and pump head can be selected according to pipe length, process loop resistance, filter pressure loss, height difference, and required water circulation rate.

What information is needed for chiller selection?

Please provide equipment type, heat load or equipment power, target water temperature, water flow rate, pump head, ambient temperature, working hours, voltage, and installation environment.

Can APT provide high ambient temperature design?

Yes. APT can provide T3 high ambient design for hot regions, with condenser, fan, compressor, and system configuration selected according to site temperature and operating conditions.

Can the evaporator material be customized?

Yes. APT can configure tank coil, shell and tube, plate, or other evaporator directions according to process water quality, corrosion risk, flow rate, and application requirements.

How does APT test the chiller before shipment?

APT performs factory testing before shipment, including refrigeration operation, water circulation, electrical protection, controller function, alarm function, and overall performance inspection.

Final CTA

Need a 25HP Air Cooled Chiller for Your Cooling Process?

Tell us your application, heat load, required water temperature, water flow, ambient temperature, voltage, and installation conditions. APT engineers will help recommend a suitable 25HP air cooled chiller or another model if your process requires a different capacity.

滚动至顶部