Products / Air-Cooled Chillers / 3HP Compact Air-Cooled Industrial Chiller
3HP Compact Cooling Platform

3HP Compact Air-Cooled Industrial Chiller with Built-In Water Tank

A compact 3HP air-cooled industrial chiller designed for small process cooling applications requiring stable chilled water, easy installation, built-in water circulation, and air-cooled heat rejection without a cooling tower.

3HP Compact Cooling
Built-In Water Tank
Air-Cooled Condenser
Top Discharge Fan
Custom Voltage & Pump
3HP compact air-cooled industrial chiller with top discharge fan, control panel and pressure gauges
Quick Answer

Quick Answer

A 3HP compact air-cooled industrial chiller is a small process cooling unit designed for equipment that requires stable chilled water but does not need a large central cooling system. With an air-cooled condenser, built-in water tank, coil heat exchange structure, control panel, pressure gauges and compact cabinet, it is suitable for laser machines, laboratory equipment, small molds, CNC auxiliary systems, water tanks and general industrial process cooling.

For selection, the key review points are heat load, target water temperature, water flow, pump head, ambient temperature, voltage, installation space and water quality.

Approx. 8-9 kW Cooling Capacity

Suitable for small process loops, compact equipment and independent chilled water supply.

Built-In Tank & Coil Structure

Integrated water circulation structure helps simplify installation and daily operation.

No Cooling Tower Required

Air-cooled heat rejection avoids plant cooling water dependence in many small installations.

Product Overview

Compact 3HP Air-Cooled Chiller for Small Process Cooling

This 3HP compact air-cooled chiller is designed for small industrial equipment and process water cooling applications. It integrates refrigeration, air-cooled condenser, water tank, pump configuration and control system into one compact cabinet. For users who need an independent chilled water source but do not require a large central chiller system, this 3HP unit provides a practical and easy-to-install cooling solution.

  • Air-cooled design with no cooling tower required for normal use conditions.
  • Built-in water tank and internal water circulation structure for more convenient setup.
  • Top discharge axial fan helps move hot condenser air upward in compact spaces.
  • Front control panel and pressure gauges support daily observation and operation review.
  • Voltage, pump, tank, evaporator and control configuration can be adjusted by project.
Back view of 3HP air-cooled chiller with water inlet and outlet connections
Rear and side structure view showing water connection area, side ventilation panels, cabinet layout and top discharge fan arrangement for compact industrial water cooling.
Key Features

Key Features of the 3HP Compact Air-Cooled Chiller

3HP Compact Cooling

Approx. 8-9 kW cooling capacity for small equipment, test systems and process water loops.

Air-Cooled Condenser

No cooling tower is required. The condenser rejects heat directly to ambient air.

Built-In Water Tank

Integrated water storage supports convenient chilled water circulation and system installation.

Coil Heat Exchange Structure

Tank coil or coil-based heat exchange structure can be configured for general water cooling applications.

Top Discharge Fan

The axial fan releases hot condenser air upward, helping reduce side heat accumulation.

Easy Operation and Maintenance

Front control panel, pressure gauges and accessible cabinet design support daily inspection and maintenance.

Application Matrix

Application Fit Matrix

Use this matrix to check whether a 3HP compact air-cooled chiller is suitable for your process cooling application.

Application Fit Level Engineering Notes Related Direction
Laser equipment Good Suitable for small laser systems requiring stable chilled water, compact installation and controlled water temperature. Review Laser Cooling
Laboratory equipment Good Suitable for reaction baths, test loops, instruments and temperature-controlled water circulation. Review Laboratory Applications
Small injection molding Conditional Suitable for small molds or auxiliary cooling when the heat load is within the 3HP cooling range. Review Injection Molding Cooling
CNC spindle or auxiliary cooling Conditional Selection should be confirmed according to spindle power, water flow and required temperature stability. Review Process Applications
Fish tank or water tank cooling Good Water quality, evaporator material and temperature range should be confirmed before selection. Submit Cooling Requirements
High ambient outdoor installation Custom required Condenser size, fan airflow and compressor selection should be checked for high ambient conditions. Review High Ambient Chiller
Technical Data

Technical Data - 3HP Compact Air-Cooled Chiller

The following data is for preliminary reference. Final configuration should be confirmed according to cooling capacity, ambient temperature, water flow, pump head, voltage and application requirements.

ModelAC-3HP
Cooling CapacityApprox. 8-9 kW
Compressor Power3 HP
CondenserAir-cooled fin and tube condenser
Fan TypeTop discharge axial fan
EvaporatorTank coil / coil heat exchanger / customizable
Water TankBuilt-in water tank
Temperature Control Range5°C - 35°C
Temperature Accuracy±1°C
RefrigerantR410A / customizable
PumpCustomizable flow and head
Power Supply220V / 380V / 415V, 50Hz / 60Hz, customizable
ProtectionHigh and low pressure protection, overload protection, compressor protection
CabinetCompact cabinet with caster wheels

Note: The above values are approximate and for preliminary selection only. Final configuration should be confirmed according to the project requirement.

Selection Guide

3HP Chiller Selection Matrix

This matrix helps determine whether a 3HP air-cooled chiller is the correct starting point for your cooling requirement.

Cooling Requirement Recommended Choice Selection Notes
Small equipment below approx. 8-9 kW heat load 3HP air-cooled chiller Suitable when the required water temperature and ambient conditions are within standard operating range.
Heat load above 10 kW 5HP chiller or larger A larger chiller should be selected to avoid insufficient cooling and unstable water temperature.
Poor room ventilation Top discharge air-cooled or water-cooled design Heat rejection method should be reviewed to avoid condenser hot air recirculation.
Corrosive water, seafood tank or special water quality Stainless steel or corrosion-resistant water contact parts Evaporator material and water circuit design should be confirmed before production.
High ambient temperature Custom air-cooled chiller Condenser, fan airflow and compressor selection should be designed according to ambient temperature.
Back view of 3HP air-cooled chiller with water inlet and outlet connections
Rear structure view for installation review, showing water connections, cabinet arrangement, side ventilation and top fan location.
Installation Notes

Product Details and Installation Notes

For small industrial cooling projects, the installation condition often affects performance as much as the nominal cooling capacity. Please review the following points before final confirmation.

Keep enough clearance around the side ventilation panels.
Keep the top fan outlet open for smooth hot air discharge.
Install the chiller on a flat and stable floor.
Confirm water inlet and outlet direction before connecting the process loop.
Improve room ventilation if the chiller is installed indoors.
Confirm water quality when the chiller is used for tanks, aquaculture or special fluids.
Custom Options

Customizable for Your Cooling Requirement

Although this is a standard compact 3HP chiller platform, APT can adjust the configuration according to the customer's process, installation environment and country power supply.

Voltage & Frequency

220V, 380V, 415V, 50Hz or 60Hz can be reviewed according to destination and project demand.

Pump Flow and Head

Pump selection can be adjusted for loop resistance, process distance and circulation requirement.

Water Tank Volume

Tank size can be reviewed according to loop volume, buffer effect and installation preference.

Evaporator Material

Water contact materials can be selected according to water quality, corrosion risk and application type.

Refrigerant

Refrigerant direction can be reviewed according to destination, service condition and engineering request.

Controller and Alarm

Controller logic, alarms and communication interface can be aligned with the process requirement.

Cabinet Size

Cabinet structure can be adjusted according to plant layout, equipment-side space and maintenance access.

Caster Wheels and Mobility

Mobility options can be included when the unit needs flexible positioning in compact equipment areas.

Quote Checklist

Quote Information Checklist

To recommend a suitable 3HP compact air-cooled chiller, please prepare the following cooling requirement information.

Application industry or cooling object

Required water temperature range

Heat load or equipment power

Water flow rate and pump head

Ambient temperature around the chiller

Power supply voltage and frequency

Installation space and ventilation condition

Water quality and water contact material requirements

Required tank volume or pump configuration

Control, alarm or communication requirements

FAQ

FAQ About 3HP Compact Air-Cooled Industrial Chillers

What is a 3HP air-cooled chiller?

A 3HP air-cooled chiller is a compact industrial water chiller that uses an air-cooled condenser to remove heat from process water. It is commonly used for small equipment, laboratory systems, laser machines, water tanks and general process cooling.

How much cooling capacity does a 3HP chiller provide?

A typical 3HP air-cooled chiller provides approximately 8-9 kW of cooling capacity, depending on chilled water temperature, ambient temperature, compressor selection, condenser size and pump configuration.

Does this chiller need a cooling tower?

No. This is an air-cooled chiller, so it rejects heat through the air-cooled condenser and does not require a cooling tower or cooling water system.

What applications are suitable for a 3HP compact chiller?

It can be used for small laser equipment, laboratory instruments, reaction baths, small molds, auxiliary CNC cooling, water tanks, fish tanks and other small process cooling applications.

Can the water tank and pump be customized?

Yes. APT can customize water tank volume, pump flow rate, pump head and water circuit configuration according to the customer's process requirement.

Can this 3HP chiller be used for laser cooling?

Yes. It can be configured as a laser cooling chiller for small laser machines when the required cooling capacity, water flow and temperature accuracy match the equipment requirement.

Can this chiller be used for laboratory cooling?

Yes. It is suitable for laboratory cooling water circulation, test loops, reaction baths and instruments that require stable chilled water in a compact installation space.

What clearance is required for the condenser and top fan?

The side ventilation panels should have enough air intake space, and the top fan outlet should remain open so hot air can discharge smoothly. Final clearance should be confirmed according to installation conditions.

Can APT supply 220V, 380V or 415V versions?

Yes. Voltage and frequency can be customized according to the destination country, including 220V, 380V, 415V, 50Hz or 60Hz configurations.

How do I know whether 3HP is enough for my process?

The correct chiller capacity should be selected based on heat load, required water temperature, water flow, ambient temperature, working time and insulation conditions. APT can help review these parameters and recommend a suitable model.

Can the evaporator material be customized?

Yes. Water contact materials and evaporator structure can be selected according to water quality and application requirements, including stainless steel options when corrosion resistance is needed.

Is this chiller suitable for high ambient temperature?

Standard air-cooled chillers should be checked carefully for high ambient conditions. For hot climates or outdoor installation, APT can customize condenser size, fan airflow and compressor selection.

Final CTA

Need a 3HP Compact Air-Cooled Chiller for Your Equipment?

Tell us your application, water temperature, heat load, power supply, water flow and installation conditions. APT engineers will help recommend a suitable 3HP compact air-cooled chiller or a larger model if your process requires more cooling capacity.

滚动至顶部
Chat on WhatsApp