50HP Air Cooled Chiller for Heavy-Duty Process Cooling
APT 50HP air cooled chiller provides heavy-duty process cooling for centralized industrial cooling, multi-point loops, production equipment, die casting auxiliary cooling, extrusion, hydraulic systems, chemical process loops, process tanks, thermal spray auxiliary cooling, and general industrial temperature control. Pump, evaporator, voltage, controller, cabinet layout, condenser design, refrigeration circuits, and high ambient configuration can be customized according to project requirements.
When Should You Choose a 50HP Air Cooled Chiller?
A 50HP air cooled chiller is suitable for heavy-duty industrial process cooling where approximately 125-150 kW cooling capacity is required without using a cooling tower. It is commonly selected for centralized industrial cooling, multi-point cooling loops, production equipment, extrusion, hydraulic systems, chemical process loops, die casting auxiliary cooling, process tanks, and thermal spray auxiliary cooling. Final configuration should be confirmed according to total heat load, water temperature, water flow, pump pressure, ambient temperature, condenser ventilation, voltage, and system layout.
Reviewed for heavy-duty cooling loads where smaller air cooled directions no longer provide enough capacity margin.
Air cooled installation reduces dependence on plant condenser water while keeping centralized cooling possible.
APT can adapt hydraulic, thermal, electrical, and control details to the actual process system and distribution loop.
Heavy-Duty 50HP Air Cooled Chiller for Industrial Process Cooling
The 50HP air cooled chiller is a heavy-duty industrial cooling unit for equipment and process lines that require higher cooling capacity, multi-point water distribution, and stable operation under long duty cycles. With an air cooled condenser, industrial compressor configuration, process water circuit, circulation pump, controller, and customizable evaporator configuration, it can be used as an independent cooling source for production equipment, hydraulic systems, process tanks, extrusion lines, chemical process loops, centralized small loops, and machine-side cooling systems.
Key Features of the 50HP Air Cooled Industrial Chiller
50HP Cooling Capacity
Approx. 125-150 kW cooling capacity for heavy-duty industrial process cooling.
Air Cooled Condenser
No cooling tower is required, making installation simpler when plant cooling water is not available.
Industrial Compressor Configuration
Compressor and refrigeration circuit configuration can be selected for stable continuous industrial operation.
Custom Pump and Evaporator
Pump flow, pump head, evaporator type, and water circuit can be configured according to project needs.
Large Heat Rejection Design
Condenser airflow, fan configuration, and cabinet layout should be reviewed according to ambient temperature and installation ventilation.
Export Voltage and Control
Voltage, frequency, controller, alarm output, and protection logic can be customized for destination markets.
Application Fit Matrix
Use this matrix to check whether a 50HP air cooled chiller is suitable for your industrial cooling application.
| Application | Fit Level | Typical Cooling Need | Engineering Review |
|---|---|---|---|
| Centralized Industrial Cooling | High | Multi-point cooling loops, factory process water cooling, continuous operation | Total heat load, system layout, water distribution, pump pressure, redundancy |
| Production Equipment Cooling | High | Heavy-duty production equipment, process water cooling, machine-side loops | Heat load, duty cycle, water flow, operating schedule, service access |
| Hydraulic System Cooling | High | Hydraulic oil cooling with heat exchanger or process water loop | Oil heat load, exchanger type, water flow, pump pressure, material compatibility |
| Chemical Process Cooling | Medium to High | Chemical process loop, tank cooling, temperature control | Fluid compatibility, evaporator material, heat load, safety requirement |
| Extrusion Cooling | Medium to High | Extrusion line cooling, process water loop, production temperature control | Heat load, duty cycle, water flow, tank volume, ambient temperature |
| Die Casting Auxiliary Cooling | Medium to High | Auxiliary cooling for die casting equipment, molds or hydraulic systems | Heat load, water temperature, pump pressure, duty cycle |
| Thermal Spray Auxiliary Cooling | Medium | Auxiliary cooling for process equipment and supporting systems | Heat load, operating schedule, ambient temperature, pump pressure |
| General Process Tank Cooling | Medium to High | Large process water tank or machine-side temperature control | Tank size, heat load, insulation, ambient temperature, pump head |
Technical Data - 50HP Air Cooled Chiller
The following data is for preliminary reference. Final configuration should be confirmed according to cooling capacity, ambient temperature, water flow, pump head, voltage, evaporator type, refrigeration circuit, and process requirements.
| Model | AC-50HP |
| Cooling Capacity | Approx. 125-150 kW / 36-43 TR reference |
| Compressor Power | 50 HP |
| Compressor Type | Scroll compressor / semi-hermetic / project dependent |
| Cooling Method | Air cooled |
| Condenser | Copper tube aluminum fin air cooled condenser |
| Evaporator | Shell and tube / plate / tank coil / customizable |
| Temperature Control Range | 5°C - 35°C |
| Temperature Accuracy | ±1°C |
| Refrigerant | R407C / R410A / R134a, project dependent |
| Pump | Customizable flow and head |
| Power Supply | 3PH 380V 50Hz / customizable |
| Refrigeration Circuits | Single or multiple circuits, project dependent |
| Protection | High and low pressure, overload, phase, flow and anti-freeze protection |
| Control | Digital controller / PLC optional |
| Cabinet | Standard or customized industrial cabinet |
50HP Chiller Selection Matrix
Use this matrix to decide whether a 50HP air cooled chiller is the right starting point or whether a smaller, water cooled, or custom chiller direction should be reviewed.
| Cooling Requirement | Recommended Direction | Best For | Engineering Review | Next Step |
|---|---|---|---|---|
| Smaller heat load around 75-90 kW | 30HP Air Cooled Chiller | Production lines, hydraulic cooling, chemical process loops, large process tanks | Heat load, water flow, pump head, installation ventilation | View 30HP Chiller Page → |
| High ambient or hot-climate installation | 40HP High Ambient Air Cooled Chiller | Middle East, hot workshops, outdoor high ambient cooling | Ambient temperature, condenser margin, airflow, compressor selection | View 40HP T3 Chiller Page → |
| Heavy-duty cooling around 125-150 kW | 50HP Air Cooled Chiller | Centralized industrial cooling, multi-point loops, heavy-duty equipment | Total heat load, water temperature, pump flow, duty cycle, system layout | Submit 50HP Requirements → |
| Poor indoor ventilation or plant cooling water available | Water Cooled Industrial Chiller | Indoor rooms, larger cooling loops, stable plant water systems | Cooling water availability, tower loop, pump pressure, installation layout | View Water Cooled Chillers → |
| Special process, voltage, evaporator, corrosion-resistant, or OEM requirement | Custom Industrial Chiller | Special fluids, OEM integration, stainless steel water contact parts, hazardous layout review | Material compatibility, controls, voltage, cabinet layout, evaporator material | View Custom Chillers → |
Customizable for Your Cooling Requirement
APT can customize this 50HP air cooled chiller according to the customer's process, installation environment, and destination country power supply.
Pump Flow and Head
Match circulation performance to total pipe resistance, distribution loops, and required process flow.
Evaporator Type
Review shell and tube, plate, tank coil, or project-specific evaporator direction.
Condenser Airflow
Check fan arrangement and airflow path for hotter workshops and dense installation layouts.
Refrigeration Circuits
Select single or multiple refrigeration circuits according to redundancy, staging, and process duty.
Voltage and Frequency
Support export electrical standards and project-specific power requirements.
Controller and Alarm
Optional PLC, HMI, alarm, and communication logic for centralized cooling integration.
Cabinet Layout
Cabinet structure and service access can be adapted to site layout and maintenance logic.
High Ambient Design
Condenser margin and thermal protection can be reviewed for hot climate installation.
Quote Information Checklist
To recommend a suitable 50HP air cooled chiller, please prepare the following cooling requirement information before quotation review.
Application industry or cooling object
Required cooling capacity or total heat load
Inlet and outlet water temperature
Water flow rate and pump head
Ambient temperature around the chiller
Power supply voltage and frequency
Installation space and ventilation condition
Water quality and evaporator material requirements
Required pump configuration or system layout
Control, alarm or communication requirements
Explore Related APT Cooling Solutions
Air Cooled Chillers
Review the full air cooled industrial chiller category before final model selection.
Open Air Cooled Category →30HP Air Cooled Chiller
Compare the 50HP direction with a smaller large-process air cooled chiller page.
Review 30HP Chiller →40HP High Ambient Air Cooled Chiller
Review a T3 high ambient direction for hotter regions or harsher condenser conditions.
Review 40HP T3 Chiller →Water Cooled Chillers
Consider water cooled direction if plant water systems are available or ventilation is limited.
Review Water Cooled →Industrial Chiller Selection Tool
Prepare preliminary cooling data before sending the engineering review request.
Use Selection Tool →Request a Quote
Submit project data for a formal engineering recommendation and quotation review.
Request Quotation →FAQ About 50HP Air Cooled Chillers
It is commonly used for centralized industrial cooling, multi-point process cooling loops, production equipment, hydraulic cooling, chemical process loops, extrusion, die casting auxiliary cooling, thermal spray auxiliary cooling, process tanks, and general industrial process cooling.
A typical 50HP air cooled chiller provides approximately 125-150 kW cooling capacity depending on chilled water temperature, ambient temperature, compressor selection, condenser size, and pump configuration.
No. An air cooled chiller rejects heat through its condenser and fan system, so it does not require a cooling tower. Good condenser airflow, installation ventilation, and service clearance are still important.
Yes. APT can customize pump pressure, evaporator type, voltage, controller, outlet direction, condenser design, refrigeration circuits, high ambient configuration, and cabinet layout based on working conditions.
Yes. A 50HP air cooled chiller can support centralized or multi-point process cooling when total heat load, water distribution, pump pressure, and control strategy are properly reviewed.
It can be suitable for heavy-duty equipment and larger process loops, but final selection should be based on total heat load, required water flow, operating hours, ambient temperature, and heat load margin.
Air cooled chillers are easier to install because they do not require a cooling tower. Water cooled models may be preferred when plant water systems are available, indoor ventilation is limited, or higher heat rejection efficiency is required.
Yes. Pump flow and pump head can be selected according to pipe length, process loop resistance, filter pressure loss, height difference, and required water circulation rate.
Please provide equipment type, total heat load, target water temperature, water flow rate, pump head, ambient temperature, working hours, voltage, installation layout, and whether centralized cooling or multiple loops are required.
Yes. APT can provide T3 high ambient design for hot regions, with condenser, fan, compressor, and system configuration selected according to site temperature and operating conditions.
Yes. APT can configure shell and tube, plate, tank coil, or other evaporator directions according to process water quality, corrosion risk, flow rate, and application requirements.
APT performs factory testing before shipment, including refrigeration operation, water circulation, electrical protection, controller function, alarm function, and overall performance inspection.
Need a 50HP Air Cooled Chiller for Your Cooling Process?
Tell us your application, total heat load, required water temperature, water flow, ambient temperature, voltage, installation layout, and whether your process needs centralized cooling or multiple loops. APT engineers will help recommend a suitable 50HP air cooled chiller or another model if your process requires a different capacity.