Home / Products / Air Cooled Chillers / 15HP Air Cooled Chiller
15HP Air Cooled Chiller

15HP Air Cooled Chiller for Medium-Duty Process Cooling

APT 15HP air cooled chiller provides medium-duty process cooling for injection molding, CNC machining, laser equipment, electroplating, thermal spray auxiliary cooling, process tanks, laboratory systems, and general industrial temperature control. Pump, tank, evaporator, voltage, controller, cabinet layout, and high ambient design can be customized according to project requirements.

Approx. 44 kW Cooling Capacity
Air Cooled Condenser
Medium-Duty Process Cooling
Custom Pump & Tank
Export Voltage Options
15HP air cooled industrial chiller for medium duty process cooling by APT Industrial Chiller
Quick Answer

Quick Answer

A 15HP air cooled chiller is suitable for medium-duty industrial process cooling where approximately 44 kW cooling capacity is required without using a cooling tower. It is commonly selected for injection molding machines, CNC machining, laser equipment, electroplating tanks, thermal spray auxiliary cooling, laboratory water circulation, and process tank temperature control. Final configuration should be confirmed according to heat load, water temperature, water flow, pump pressure, ambient temperature, voltage, and installation ventilation.

Approx. 44 kW Cooling Capacity
No Cooling Tower Required
Custom Pump, Tank and Voltage
Product Overview

Medium-Duty 15HP Air Cooled Chiller for Industrial Process Cooling

The 15HP air cooled chiller is a practical medium-duty cooling unit for industrial equipment that requires higher cooling capacity than a compact model but still benefits from simple air cooled installation. With an air cooled condenser, scroll compressor, process water circuit, circulation pump, controller, and optional water tank or evaporator configuration, it can be used as an independent cooling source for production equipment, process tanks, and machine-side cooling loops.

  • Suitable for medium-duty process cooling loads
  • Higher capacity than 10HP models
  • No cooling tower required
  • Supports equipment-side and process tank cooling
  • Can be customized for pump, tank, evaporator and voltage
  • Suitable for export projects and different power standards
15HP air cooled industrial chiller for medium duty process cooling by APT Industrial Chiller
Reference 15HP air cooled industrial chiller layout showing condenser section, process water circuit, cabinet structure, and industrial installation direction for medium-duty process cooling projects.
Key Features

Key Features of the 15HP Air Cooled Industrial Chiller

15HP Cooling Capacity

Approx. 44 kW cooling capacity for medium-duty industrial process cooling.

Air Cooled Condenser

No cooling tower is required, making installation simpler for workshops and equipment-side cooling.

Scroll Compressor

Reliable compressor configuration for stable refrigeration and continuous industrial operation.

Custom Pump and Tank

Pump flow, pump head, tank volume, and water circuit can be configured according to project needs.

Flexible Evaporator Options

Tank coil, shell and tube, plate, or other evaporator directions can be reviewed based on water quality and process loop.

Export Voltage and Control

Voltage, frequency, controller, alarm output, and protection logic can be customized for destination markets.

Application Matrix

Application Fit Matrix

Use this matrix to check whether a 15HP air cooled chiller is suitable for your industrial cooling application.

Application Fit Level Typical Cooling Need Engineering Review
Injection Molding Cooling High Medium mold cooling, auxiliary cooling, process water temperature control Mold heat load, tank volume, water flow, production duty cycle
CNC Machine Cooling Medium to High Multiple spindle cooling, cutting fluid tank cooling, machine-side water loop Spindle power, coolant loop, pump pressure, filtration, temperature stability
Laser Equipment Cooling Medium Laser source and auxiliary equipment cooling Laser power, water quality, temperature accuracy, flow stability
Electroplating Cooling Medium to High Plating bath temperature control and process tank cooling Tank volume, chemical compatibility, evaporator material, heat gain
Thermal Spray Auxiliary Cooling Medium Auxiliary cooling for process equipment and supporting systems Heat load, operating schedule, ambient temperature, pump pressure
General Process Tank Cooling Medium to High Process water tank or machine-side temperature control Tank size, heat load, insulation, ambient temperature, pump head
Technical Data

Technical Data - 15HP Air Cooled Chiller

The following data is for preliminary reference. Final configuration should be confirmed according to cooling capacity, ambient temperature, water flow, pump head, voltage, evaporator type, and process requirements.

Item Reference Specification
ModelAC-15HP
Cooling CapacityApprox. 44 kW / 12.5 RT / 150,000 BTU/h
Compressor Power15 HP
Compressor TypeScroll compressor
Cooling MethodAir cooled
CondenserCopper tube aluminum fin air cooled condenser
EvaporatorTank coil / shell and tube / plate / customizable
Temperature Control Range5°C - 35°C
Temperature Accuracy±1°C
RefrigerantR407C / R410A / R134a, project dependent
PumpCustomizable flow and head
Power Supply3PH 380V 50Hz / customizable
ProtectionHigh and low pressure, overload, phase, flow and anti-freeze protection
ControlDigital controller / PLC optional
CabinetStandard or customized industrial cabinet
Selection Matrix

15HP Chiller Selection Matrix

Use this matrix to decide whether a 15HP air cooled chiller is the right starting point or whether a smaller, larger, water cooled, or custom chiller direction should be reviewed.

Cooling Requirement Recommended Direction Best For Engineering Review Next Step
Smaller heat load around 29.3 kW 10HP Air Cooled Chiller Medium process cooling, single machine, moderate duty cycle Heat load, water flow, pump head, installation ventilation View 10HP Chiller Page
Medium-duty process cooling around 44 kW 15HP Air Cooled Chiller Injection molding, CNC, laser, electroplating, process tank cooling Cooling capacity, water temperature, pump flow, ambient temperature Submit 15HP Requirements
Higher heat load above approx. 55-60 kW 20HP Air Cooled Chiller Larger molds, multiple machines, higher duty cycles Heat load margin, pump pressure, condenser ventilation View 20HP Chiller Page
Poor indoor ventilation or plant cooling water available Water Cooled Industrial Chiller Indoor rooms, larger cooling loops, stable plant water systems Cooling water availability, tower loop, pump pressure, installation layout View Water Cooled Chillers
Special process, voltage, evaporator, or high ambient condition Custom Industrial Chiller Special fluids, T3 regions, OEM integration, corrosion-resistant requirements Ambient temperature, material compatibility, controls, voltage, cabinet layout View Custom Chillers
Customization

Customizable for Your Cooling Requirement

APT can customize this 15HP air cooled chiller according to the customer's process, installation environment, and destination country power supply.

Pump Flow and Head

Select pump capacity according to pipe resistance, circulation rate, and machine-side cooling requirement.

Water Tank Volume

Adjust tank volume according to process water volume, buffering demand, and temperature stability.

Evaporator Type

Review tank coil, shell and tube, plate, or other evaporator directions according to water quality and process loop.

Voltage and Frequency

Support project-specific export voltage, phase, and frequency standards for overseas installations.

Controller and Alarm

Configure digital controller, PLC, remote alarm, and communication options according to site needs.

Refrigerant Direction

Select refrigerant direction according to destination market, service conditions, and engineering review.

Cabinet Layout

Adjust cabinet structure, service access, piping direction, and installation footprint for project layout.

High Ambient Design

Provide T3 high ambient review for hot regions, outdoor layouts, and demanding workshop conditions.

Quote Checklist

Quote Information Checklist

To recommend a suitable 15HP air cooled chiller, please prepare the following cooling requirement information before quotation review.

Application industry or cooling object

Required cooling capacity or heat load

Inlet and outlet water temperature

Water flow rate and pump head

Ambient temperature around the chiller

Power supply voltage and frequency

Installation space and ventilation condition

Water quality and evaporator material requirements

Required tank volume or pump configuration

Control, alarm or communication requirements

FAQ

FAQ About 15HP Air Cooled Chillers

What applications is a 15HP air cooled chiller suitable for?

It is commonly used for injection molding, CNC machining, laser equipment, electroplating, thermal spray auxiliary cooling, process tanks, laboratory systems, and general industrial process cooling.

What cooling capacity does a 15HP air cooled chiller provide?

A typical 15HP air cooled chiller provides approximately 44 kW cooling capacity, but actual performance depends on chilled water temperature, ambient temperature, compressor selection, condenser size, and pump configuration.

Does a 15HP air cooled chiller need a cooling tower?

No. An air cooled chiller rejects heat through its condenser and fan system, so it does not require a cooling tower. Good condenser airflow and installation ventilation are still important.

Can the 15HP chiller be customized for my process?

Yes. APT can customize pump pressure, water tank size, evaporator type, voltage, controller, outlet direction, condenser design, and high ambient configuration based on working conditions.

Can a 15HP chiller be used for injection molding cooling?

Yes. A 15HP air cooled chiller can be used for injection molding auxiliary cooling when the mold heat load, tank volume, water flow, and production duty cycle match the chiller capacity.

Is 15HP enough for multiple machines?

It may be suitable for multiple small machines, but the final selection should be based on total heat load, required water flow, operating hours, and heat load margin.

Is air cooled or water cooled better for a 15HP chiller?

Air cooled chillers are easier to install because they do not require a cooling tower. Water cooled models may be preferred when plant water systems are available or when installation space and ambient temperature require a different design.

Can APT customize pump flow and pump head?

Yes. Pump flow and pump head can be selected according to pipe length, process loop resistance, filter pressure loss, height difference, and required water circulation rate.

What information is needed for chiller selection?

Please provide equipment type, heat load or equipment power, target water temperature, water flow rate, pump head, ambient temperature, working hours, voltage, and installation environment.

Can APT provide high ambient temperature design?

Yes. APT can provide T3 high ambient design for hot regions, with condenser, fan, compressor, and system configuration selected according to site temperature and operating conditions.

Can the evaporator material be customized?

Yes. APT can configure tank coil, shell and tube, plate, or other evaporator directions according to process water quality, corrosion risk, flow rate, and application requirements.

How does APT test the chiller before shipment?

APT performs factory testing before shipment, including refrigeration operation, water circulation, electrical protection, controller function, alarm function, and overall performance inspection.

Final CTA

Need a 15HP Air Cooled Chiller for Your Cooling Process?

Tell us your application, heat load, required water temperature, water flow, ambient temperature, voltage, and installation conditions. APT engineers will help recommend a suitable 15HP air cooled chiller or another model if your process requires a different capacity.

滚动至顶部
Chat on WhatsApp