15HP Air Cooled Chiller for Medium-Duty Process Cooling
APT 15HP air cooled chiller provides medium-duty process cooling for injection molding, CNC machining, laser equipment, electroplating, thermal spray auxiliary cooling, process tanks, laboratory systems, and general industrial temperature control. Pump, tank, evaporator, voltage, controller, cabinet layout, and high ambient design can be customized according to project requirements.
Quick Answer
A 15HP air cooled chiller is suitable for medium-duty industrial process cooling where approximately 44 kW cooling capacity is required without using a cooling tower. It is commonly selected for injection molding machines, CNC machining, laser equipment, electroplating tanks, thermal spray auxiliary cooling, laboratory water circulation, and process tank temperature control. Final configuration should be confirmed according to heat load, water temperature, water flow, pump pressure, ambient temperature, voltage, and installation ventilation.
Medium-Duty 15HP Air Cooled Chiller for Industrial Process Cooling
The 15HP air cooled chiller is a practical medium-duty cooling unit for industrial equipment that requires higher cooling capacity than a compact model but still benefits from simple air cooled installation. With an air cooled condenser, scroll compressor, process water circuit, circulation pump, controller, and optional water tank or evaporator configuration, it can be used as an independent cooling source for production equipment, process tanks, and machine-side cooling loops.
- Suitable for medium-duty process cooling loads
- Higher capacity than 10HP models
- No cooling tower required
- Supports equipment-side and process tank cooling
- Can be customized for pump, tank, evaporator and voltage
- Suitable for export projects and different power standards
Key Features of the 15HP Air Cooled Industrial Chiller
15HP Cooling Capacity
Approx. 44 kW cooling capacity for medium-duty industrial process cooling.
Air Cooled Condenser
No cooling tower is required, making installation simpler for workshops and equipment-side cooling.
Scroll Compressor
Reliable compressor configuration for stable refrigeration and continuous industrial operation.
Custom Pump and Tank
Pump flow, pump head, tank volume, and water circuit can be configured according to project needs.
Flexible Evaporator Options
Tank coil, shell and tube, plate, or other evaporator directions can be reviewed based on water quality and process loop.
Export Voltage and Control
Voltage, frequency, controller, alarm output, and protection logic can be customized for destination markets.
Application Fit Matrix
Use this matrix to check whether a 15HP air cooled chiller is suitable for your industrial cooling application.
| Application | Fit Level | Typical Cooling Need | Engineering Review |
|---|---|---|---|
| Injection Molding Cooling | High | Medium mold cooling, auxiliary cooling, process water temperature control | Mold heat load, tank volume, water flow, production duty cycle |
| CNC Machine Cooling | Medium to High | Multiple spindle cooling, cutting fluid tank cooling, machine-side water loop | Spindle power, coolant loop, pump pressure, filtration, temperature stability |
| Laser Equipment Cooling | Medium | Laser source and auxiliary equipment cooling | Laser power, water quality, temperature accuracy, flow stability |
| Electroplating Cooling | Medium to High | Plating bath temperature control and process tank cooling | Tank volume, chemical compatibility, evaporator material, heat gain |
| Thermal Spray Auxiliary Cooling | Medium | Auxiliary cooling for process equipment and supporting systems | Heat load, operating schedule, ambient temperature, pump pressure |
| General Process Tank Cooling | Medium to High | Process water tank or machine-side temperature control | Tank size, heat load, insulation, ambient temperature, pump head |
Technical Data - 15HP Air Cooled Chiller
The following data is for preliminary reference. Final configuration should be confirmed according to cooling capacity, ambient temperature, water flow, pump head, voltage, evaporator type, and process requirements.
| Item | Reference Specification |
|---|---|
| Model | AC-15HP |
| Cooling Capacity | Approx. 44 kW / 12.5 RT / 150,000 BTU/h |
| Compressor Power | 15 HP |
| Compressor Type | Scroll compressor |
| Cooling Method | Air cooled |
| Condenser | Copper tube aluminum fin air cooled condenser |
| Evaporator | Tank coil / shell and tube / plate / customizable |
| Temperature Control Range | 5°C - 35°C |
| Temperature Accuracy | ±1°C |
| Refrigerant | R407C / R410A / R134a, project dependent |
| Pump | Customizable flow and head |
| Power Supply | 3PH 380V 50Hz / customizable |
| Protection | High and low pressure, overload, phase, flow and anti-freeze protection |
| Control | Digital controller / PLC optional |
| Cabinet | Standard or customized industrial cabinet |
15HP Chiller Selection Matrix
Use this matrix to decide whether a 15HP air cooled chiller is the right starting point or whether a smaller, larger, water cooled, or custom chiller direction should be reviewed.
| Cooling Requirement | Recommended Direction | Best For | Engineering Review | Next Step |
|---|---|---|---|---|
| Smaller heat load around 29.3 kW | 10HP Air Cooled Chiller | Medium process cooling, single machine, moderate duty cycle | Heat load, water flow, pump head, installation ventilation | View 10HP Chiller Page |
| Medium-duty process cooling around 44 kW | 15HP Air Cooled Chiller | Injection molding, CNC, laser, electroplating, process tank cooling | Cooling capacity, water temperature, pump flow, ambient temperature | Submit 15HP Requirements |
| Higher heat load above approx. 55-60 kW | 20HP Air Cooled Chiller | Larger molds, multiple machines, higher duty cycles | Heat load margin, pump pressure, condenser ventilation | View 20HP Chiller Page |
| Poor indoor ventilation or plant cooling water available | Water Cooled Industrial Chiller | Indoor rooms, larger cooling loops, stable plant water systems | Cooling water availability, tower loop, pump pressure, installation layout | View Water Cooled Chillers |
| Special process, voltage, evaporator, or high ambient condition | Custom Industrial Chiller | Special fluids, T3 regions, OEM integration, corrosion-resistant requirements | Ambient temperature, material compatibility, controls, voltage, cabinet layout | View Custom Chillers |
Customizable for Your Cooling Requirement
APT can customize this 15HP air cooled chiller according to the customer's process, installation environment, and destination country power supply.
Pump Flow and Head
Select pump capacity according to pipe resistance, circulation rate, and machine-side cooling requirement.
Water Tank Volume
Adjust tank volume according to process water volume, buffering demand, and temperature stability.
Evaporator Type
Review tank coil, shell and tube, plate, or other evaporator directions according to water quality and process loop.
Voltage and Frequency
Support project-specific export voltage, phase, and frequency standards for overseas installations.
Controller and Alarm
Configure digital controller, PLC, remote alarm, and communication options according to site needs.
Refrigerant Direction
Select refrigerant direction according to destination market, service conditions, and engineering review.
Cabinet Layout
Adjust cabinet structure, service access, piping direction, and installation footprint for project layout.
High Ambient Design
Provide T3 high ambient review for hot regions, outdoor layouts, and demanding workshop conditions.
Quote Information Checklist
To recommend a suitable 15HP air cooled chiller, please prepare the following cooling requirement information before quotation review.
Application industry or cooling object
Required cooling capacity or heat load
Inlet and outlet water temperature
Water flow rate and pump head
Ambient temperature around the chiller
Power supply voltage and frequency
Installation space and ventilation condition
Water quality and evaporator material requirements
Required tank volume or pump configuration
Control, alarm or communication requirements
Explore Related APT Cooling Solutions
Air Cooled Chillers
Explore the broader air cooled chiller range for compact, medium, large, and custom industrial process cooling systems.
View Air Cooled Chillers Related Model10HP Air Cooled Chiller
Compare a slightly smaller air cooled chiller direction for moderate industrial process cooling loads.
Review 10HP Model Related Model20HP Air Cooled Chiller
Move up to a larger process cooling direction when heat load or duty cycle exceeds the 15HP range.
Review 20HP Model Related Model25HP Air Cooled Chiller
Review a larger-capacity process cooling direction for heavier industrial heat loads and multiple loops.
Review 25HP Model Selection ToolIndustrial Chiller Selection Tool
Organize cooling load, water temperature, flow, pump pressure, voltage, and application data before quotation.
Use Selection Tool QuoteRequest a Quote
Submit your process cooling requirement for engineering review and a tailored chiller recommendation.
Submit RequirementsFAQ About 15HP Air Cooled Chillers
What applications is a 15HP air cooled chiller suitable for?
It is commonly used for injection molding, CNC machining, laser equipment, electroplating, thermal spray auxiliary cooling, process tanks, laboratory systems, and general industrial process cooling.
What cooling capacity does a 15HP air cooled chiller provide?
A typical 15HP air cooled chiller provides approximately 44 kW cooling capacity, but actual performance depends on chilled water temperature, ambient temperature, compressor selection, condenser size, and pump configuration.
Does a 15HP air cooled chiller need a cooling tower?
No. An air cooled chiller rejects heat through its condenser and fan system, so it does not require a cooling tower. Good condenser airflow and installation ventilation are still important.
Can the 15HP chiller be customized for my process?
Yes. APT can customize pump pressure, water tank size, evaporator type, voltage, controller, outlet direction, condenser design, and high ambient configuration based on working conditions.
Can a 15HP chiller be used for injection molding cooling?
Yes. A 15HP air cooled chiller can be used for injection molding auxiliary cooling when the mold heat load, tank volume, water flow, and production duty cycle match the chiller capacity.
Is 15HP enough for multiple machines?
It may be suitable for multiple small machines, but the final selection should be based on total heat load, required water flow, operating hours, and heat load margin.
Is air cooled or water cooled better for a 15HP chiller?
Air cooled chillers are easier to install because they do not require a cooling tower. Water cooled models may be preferred when plant water systems are available or when installation space and ambient temperature require a different design.
Can APT customize pump flow and pump head?
Yes. Pump flow and pump head can be selected according to pipe length, process loop resistance, filter pressure loss, height difference, and required water circulation rate.
What information is needed for chiller selection?
Please provide equipment type, heat load or equipment power, target water temperature, water flow rate, pump head, ambient temperature, working hours, voltage, and installation environment.
Can APT provide high ambient temperature design?
Yes. APT can provide T3 high ambient design for hot regions, with condenser, fan, compressor, and system configuration selected according to site temperature and operating conditions.
Can the evaporator material be customized?
Yes. APT can configure tank coil, shell and tube, plate, or other evaporator directions according to process water quality, corrosion risk, flow rate, and application requirements.
How does APT test the chiller before shipment?
APT performs factory testing before shipment, including refrigeration operation, water circulation, electrical protection, controller function, alarm function, and overall performance inspection.
Need a 15HP Air Cooled Chiller for Your Cooling Process?
Tell us your application, heat load, required water temperature, water flow, ambient temperature, voltage, and installation conditions. APT engineers will help recommend a suitable 15HP air cooled chiller or another model if your process requires a different capacity.