Home / Products / Air Cooled Chillers / 10HP Air Cooled Chiller
10HP Air Cooled Chiller

10HP Air Cooled Chiller for Industrial Process Cooling

APT 10HP air cooled chiller provides medium-duty process cooling for injection molding, CNC machining, laser equipment, electroplating, laboratory water circulation, machine cooling, and general industrial temperature control. Pump, tank, evaporator, voltage, controller, cabinet layout, and high ambient design can be customized according to project requirements.

Approx. 29.3 kW Cooling Capacity
Air Cooled Condenser
Custom Pump & Tank
5°C-35°C Temperature Range
Export Voltage Options
10HP air cooled industrial chiller for process cooling by APT Industrial Chiller
Quick Answer

Quick Answer

A 10HP air cooled chiller is suitable for medium process cooling loads where approximately 29.3 kW cooling capacity is required without using a cooling tower. It is commonly selected for injection molding auxiliary cooling, CNC machining, laser equipment, electroplating tanks, laboratory water circulation, machine cooling, and general industrial temperature control. Final configuration should be confirmed according to heat load, water temperature, water flow, pump pressure, ambient temperature, voltage, and installation ventilation.

Approx. 29.3 kW / 8.3 RT
No Cooling Tower Required
Custom Pump, Tank and Voltage
Product Overview

Medium-Duty 10HP Air Cooled Chiller for Process Cooling

The 10HP air cooled chiller is a practical medium-duty cooling unit for industrial equipment that requires stable chilled water but does not need a large central chiller system. With an air cooled condenser, scroll compressor, process water circuit, circulation pump, controller, and optional water tank or evaporator configuration, it can be used as an independent cooling source for production equipment, process tanks, and machine-side cooling loops.

  • Suitable for medium process cooling loads
  • No cooling tower required
  • Supports equipment-side installation
  • Can be customized for pump, tank, evaporator and voltage
  • Suitable for export projects and different power standards
10HP air cooled industrial chiller for process cooling by APT Industrial Chiller
Reference 10HP air cooled industrial chiller layout with process water circuit, control cabinet, condenser section, and machine-side installation direction for medium industrial cooling applications.
Key Features

Key Features of the 10HP Air Cooled Industrial Chiller

10HP Cooling Capacity

Approx. 29.3 kW cooling capacity for medium-duty industrial process cooling.

Air Cooled Condenser

No cooling tower is required, making installation simpler for workshops and equipment-side cooling.

Scroll Compressor

Reliable compressor configuration for stable refrigeration and continuous industrial operation.

Custom Pump and Tank

Pump flow, pump head, tank volume, and water circuit can be configured according to project needs.

Flexible Evaporator Options

Tank coil, shell and tube, plate, or other evaporator directions can be reviewed based on water quality and process loop.

Export Voltage and Control

Voltage, frequency, controller, alarm output, and protection logic can be customized for destination markets.

Application Matrix

Application Fit Matrix

Use this matrix to check whether a 10HP air cooled chiller is suitable for your industrial cooling application.

Application Fit Level Typical Cooling Need Engineering Review
Injection Molding Cooling High Mold cooling, auxiliary cooling, process water temperature control Mold heat load, tank volume, water flow, production duty cycle
CNC Machine Cooling Medium to High Spindle cooling, cutting fluid tank cooling, machine-side water loop Spindle power, coolant loop, pump pressure, filtration, temperature stability
Laser Equipment Cooling Medium Laser source and auxiliary equipment cooling Laser power, water quality, temperature accuracy, flow stability
Electroplating Cooling Medium to High Plating bath temperature control and process tank cooling Tank volume, chemical compatibility, evaporator material, heat gain
Laboratory or Test Loop Cooling Medium Test bench, reaction bath, instrument water circulation Temperature range, water flow, control accuracy, operating hours
General Process Tank Cooling Medium to High Process water tank or machine-side temperature control Tank size, heat load, insulation, ambient temperature, pump head
Technical Data

Technical Data - 10HP Air Cooled Chiller

The following data is for preliminary reference. Final configuration should be confirmed according to cooling capacity, ambient temperature, water flow, pump head, voltage, evaporator type, and process requirements.

Item Reference Specification
ModelAC-10HP
Cooling CapacityApprox. 29.3 kW / 8.3 RT / 100,000 BTU/h
Compressor Power10 HP
Compressor TypeScroll compressor
Cooling MethodAir cooled
CondenserCopper tube aluminum fin air cooled condenser
EvaporatorTank coil / shell and tube / plate / customizable
Temperature Control Range5°C - 35°C
Temperature Accuracy±1°C
RefrigerantR407C / R410A / R134a, project dependent
PumpCustomizable flow and head
Power Supply3PH 380V 50Hz / customizable
ProtectionHigh and low pressure, overload, phase, flow and anti-freeze protection
ControlDigital controller / PLC optional
CabinetStandard or customized industrial cabinet
Selection Matrix

10HP Chiller Selection Matrix

Use this matrix to decide whether a 10HP air cooled chiller is the right starting point or whether a compact, larger, water cooled, or custom chiller direction should be reviewed.

Cooling Requirement Recommended Direction Best For Engineering Review Next Step
Small single machine below 8-9 kW heat load 3HP or 5HP Compact Air Cooled Chiller Small machines, compact workshops, equipment-side cooling Heat load, water flow, pump head, installation space View Compact Chillers
Medium process cooling around 29.3 kW 10HP Air Cooled Chiller Injection molding, CNC, laser, electroplating, laboratory loops Cooling capacity, water temperature, pump flow, ambient temperature Submit 10HP Requirements
Higher heat load above 35-40 kW 15HP or 20HP Air Cooled Chiller Larger molds, multiple small machines, higher duty cycles Heat load margin, pump pressure, condenser ventilation View 15HP Chiller Page
Poor indoor ventilation or plant cooling water available Water Cooled Industrial Chiller Indoor rooms, larger cooling loops, stable plant water systems Cooling water availability, tower loop, pump pressure, installation layout View Water Cooled Chillers
Special process, voltage, evaporator, or high ambient condition Custom Industrial Chiller Special fluids, T3 regions, OEM integration, corrosion-resistant requirements Ambient temperature, material compatibility, controls, voltage, cabinet layout View Custom Chillers
Customization

Customizable for Your Cooling Requirement

APT can customize this 10HP air cooled chiller according to the customer's process, installation environment, and destination country power supply.

Pump Flow and Head

Select pump capacity according to pipe resistance, circulation rate, and machine-side cooling requirement.

Water Tank Volume

Adjust tank volume according to process water volume, buffering demand, and temperature stability.

Evaporator Type

Review tank coil, shell and tube, plate, or other evaporator directions according to water quality and process loop.

Voltage and Frequency

Support project-specific export voltage, phase, and frequency standards for overseas installations.

Controller and Alarm

Configure digital controller, PLC, remote alarm, and communication options according to site needs.

Refrigerant Direction

Select refrigerant direction according to destination market, service conditions, and engineering review.

Cabinet Layout

Adjust cabinet structure, service access, piping direction, and installation footprint for project layout.

High Ambient Design

Provide T3 high ambient review for hot regions, outdoor layouts, and demanding workshop conditions.

Quote Checklist

Quote Information Checklist

To recommend a suitable 10HP air cooled chiller, please prepare the following cooling requirement information before quotation review.

Application industry or cooling object

Required cooling capacity or heat load

Inlet and outlet water temperature

Water flow rate and pump head

Ambient temperature around the chiller

Power supply voltage and frequency

Installation space and ventilation condition

Water quality and evaporator material requirements

Required tank volume or pump configuration

Control, alarm or communication requirements

FAQ

FAQ About 10HP Air Cooled Chillers

What applications is a 10HP air cooled chiller suitable for?

It is commonly used for CNC machining, plastic injection molding auxiliary cooling, laser equipment, laboratory water circulation, electroplating, chemical cooling, process tanks, and general industrial process cooling.

What cooling capacity does a 10HP air cooled chiller provide?

A typical 10HP air cooled chiller provides approximately 29.3 kW cooling capacity, but actual performance depends on chilled water temperature, ambient temperature, compressor selection, condenser size, and pump configuration.

Does a 10HP air cooled chiller need a cooling tower?

No. An air cooled chiller rejects heat through its condenser and fan system, so it does not require a cooling tower. Good condenser airflow and installation ventilation are still important.

Can the 10HP chiller be customized for my process?

Yes. APT can customize pump pressure, water tank size, evaporator type, voltage, controller, outlet direction, condenser design, and high ambient configuration based on working conditions.

Can a 10HP chiller be used for injection molding cooling?

Yes. A 10HP air cooled chiller can be used for injection molding auxiliary cooling when the mold heat load, tank volume, water flow, and production duty cycle match the chiller capacity.

Is air cooled or water cooled better for a 10HP chiller?

Air cooled chillers are easier to install because they do not require a cooling tower. Water cooled models may be preferred when plant water systems are available or when installation space and ambient temperature require a different design.

Can APT customize pump flow and pump head?

Yes. Pump flow and pump head can be selected according to pipe length, process loop resistance, filter pressure loss, height difference, and required water circulation rate.

What information is needed for chiller selection?

Please provide equipment type, heat load or equipment power, target water temperature, water flow rate, pump head, ambient temperature, working hours, voltage, and installation environment.

Can APT provide high ambient temperature design?

Yes. APT can provide T3 high ambient design for hot regions, with condenser, fan, compressor, and system configuration selected according to site temperature and operating conditions.

How do I know whether 10HP is enough for my process?

The correct chiller capacity should be selected according to heat load, target water temperature, water flow, ambient temperature, working hours, and heat load margin. APT can review these parameters before recommending a model.

Can the evaporator material be customized?

Yes. APT can configure tank coil, shell and tube, plate, or other evaporator directions according to process water quality, corrosion risk, flow rate, and application requirements.

How does APT test the chiller before shipment?

APT performs factory testing before shipment, including refrigeration operation, water circulation, electrical protection, controller function, alarm function, and overall performance inspection.

Final CTA

Need a 10HP Air Cooled Chiller for Your Cooling Process?

Tell us your application, heat load, required water temperature, water flow, ambient temperature, voltage, and installation conditions. APT engineers will help recommend a suitable 10HP air cooled chiller or another model if your process requires a different capacity.

滚动至顶部
Chat on WhatsApp