Home / Products / Air Cooled Chillers / 30HP Air Cooled Chiller
Air Cooled Chiller Series • 30HP Large Process Range

30HP Air Cooled Chiller for Large Process Cooling

APT 30HP air cooled chiller provides large process cooling for production lines, hydraulic cooling, chemical process loops, injection molding, extrusion, die casting auxiliary cooling, process tanks, electroplating, thermal spray auxiliary cooling, and general industrial temperature control. Pump, evaporator, voltage, controller, cabinet layout, condenser design, and high ambient configuration can be customized according to project requirements.

Approx. 75-90 kW Cooling Capacity Air Cooled Condenser Large Process Cooling Custom Pump & Evaporator Export Voltage Options
30HP air cooled industrial chiller for large process cooling by APT Industrial Chiller
Quick Answer

When Should You Choose a 30HP Air Cooled Chiller?

A 30HP air cooled chiller is suitable for large industrial process cooling where approximately 75-90 kW cooling capacity is required without using a cooling tower. It is commonly selected for production lines, hydraulic systems, chemical process loops, injection molding, extrusion, die casting auxiliary cooling, electroplating, process tanks, and thermal spray auxiliary cooling. Final configuration should be confirmed according to heat load, water temperature, water flow, pump pressure, ambient temperature, voltage, condenser ventilation, and installation space.

Approx. 75-90 kW Cooling Capacity

Reviewed for larger industrial cooling loads where 20HP and 25HP directions are no longer sufficient.

No Cooling Tower Required

Air cooled installation simplifies layout when plant condenser water is unavailable or not preferred.

Custom Pump, Evaporator and Voltage

APT can tailor hydraulic, thermal, electrical, and control details for the actual process system.

Product Overview

Large 30HP Air Cooled Chiller for Industrial Process Cooling

The 30HP air cooled chiller is a large industrial cooling unit for equipment and process lines that require higher cooling capacity than 20HP or 25HP models while still using air cooled heat rejection. With an air cooled condenser, compressor system, process water circuit, circulation pump, controller, and customizable evaporator configuration, it can be used as an independent cooling source for production equipment, hydraulic systems, process tanks, extrusion lines, chemical process loops, and machine-side cooling loops.

Suitable for large process cooling loads
Higher capacity than 20HP and 25HP models
No cooling tower required
Supports production line, hydraulic, chemical process and tank cooling
Can be customized for pump, evaporator, condenser and voltage
Suitable for export projects and different power standards
30HP air cooled industrial chiller application for process cooling
Key Features

Key Features of the 30HP Air Cooled Industrial Chiller

30HP Cooling Capacity

Approx. 75-90 kW cooling capacity for large industrial process cooling.

Air Cooled Condenser

No cooling tower is required, making installation simpler when plant cooling water is not available.

Industrial Compressor System

Compressor configuration can be selected for stable refrigeration and continuous industrial operation.

Custom Pump and Evaporator

Pump flow, pump head, evaporator type, and water circuit can be configured according to project needs.

Large Heat Rejection Design

Condenser airflow and fan configuration should be reviewed according to ambient temperature and installation ventilation.

Export Voltage and Control

Voltage, frequency, controller, alarm output, and protection logic can be customized for destination markets.

Application Fit Matrix

Application Fit Matrix

Use this matrix to check whether a 30HP air cooled chiller is suitable for your industrial cooling application.

Application Fit Level Typical Cooling Need Engineering Review
Production Line CoolingHighMulti-point process cooling, continuous operation, larger cooling loopTotal heat load, duty cycle, water distribution, pump pressure
Hydraulic System CoolingHighHydraulic oil cooling with heat exchanger or process water loopOil heat load, exchanger type, water flow, pump pressure, material compatibility
Chemical Process CoolingMedium to HighChemical process loop, tank cooling, temperature controlFluid compatibility, evaporator material, heat load, safety requirement
Injection Molding CoolingMedium to HighLarger mold cooling, auxiliary cooling, process water temperature controlMold heat load, tank volume, water flow, production duty cycle
Extrusion CoolingMedium to HighExtrusion line cooling, process water loop, production temperature controlHeat load, duty cycle, water flow, tank volume, ambient temperature
Electroplating CoolingMedium to HighPlating bath temperature control and process tank coolingTank volume, chemical compatibility, evaporator material, heat gain
Die Casting Auxiliary CoolingMediumAuxiliary cooling for die casting equipment, molds or hydraulic systemsHeat load, water temperature, pump pressure, duty cycle
Thermal Spray Auxiliary CoolingMediumAuxiliary cooling for process equipment and supporting systemsHeat load, operating schedule, ambient temperature, pump pressure
Technical Data

Technical Data - 30HP Air Cooled Chiller

The following data is for preliminary reference. Final configuration should be confirmed according to cooling capacity, ambient temperature, water flow, pump head, voltage, evaporator type, and process requirements.

ModelAC-30HP
Cooling CapacityApprox. 75-90 kW / 21-26 TR reference
Compressor Power30 HP
Compressor TypeScroll compressor / semi-hermetic / project dependent
Cooling MethodAir cooled
CondenserCopper tube aluminum fin air cooled condenser
EvaporatorShell and tube / plate / tank coil / customizable
Temperature Control Range5°C - 35°C
Temperature Accuracy±1°C
RefrigerantR407C / R410A / R134a, project dependent
PumpCustomizable flow and head
Power Supply3PH 380V 50Hz / customizable
ProtectionHigh and low pressure, overload, phase, flow and anti-freeze protection
ControlDigital controller / PLC optional
CabinetStandard or customized industrial cabinet
Selection Matrix

30HP Chiller Selection Matrix

Use this matrix to decide whether a 30HP air cooled chiller is the right starting point or whether a smaller, larger, water cooled, or custom chiller direction should be reviewed.

Cooling Requirement Recommended Direction Best For Engineering Review Next Step
Smaller heat load around 60-75 kW 25HP Air Cooled Chiller Large medium-duty process cooling, hydraulic systems, process tanks Heat load, water flow, pump head, installation ventilation View 25HP Chiller Page →
Large process cooling around 75-90 kW 30HP Air Cooled Chiller Production lines, hydraulic cooling, chemical process loops, injection molding Cooling capacity, water temperature, pump flow, ambient temperature Submit 30HP Requirements →
High ambient or hot-climate installation 40HP High Ambient Air Cooled Chiller Middle East, hot workshops, outdoor high ambient cooling Ambient temperature, condenser margin, airflow, compressor selection View 40HP T3 Chiller Page →
Higher heat load above approx. 100 kW 50HP Air Cooled Chiller Centralized industrial cooling, heavy-duty equipment, multi-point loops Total heat load, system layout, pump head, duty cycle View 50HP Chiller Page →
Poor indoor ventilation or plant cooling water available Water Cooled Industrial Chiller Indoor rooms, larger cooling loops, stable plant water systems Cooling water availability, tower loop, pump pressure, installation layout View Water Cooled Chillers →
Special process, voltage, evaporator, or corrosion-resistant requirement Custom Industrial Chiller Special fluids, OEM integration, stainless steel water contact parts, hazardous layout review Material compatibility, controls, voltage, cabinet layout, evaporator material View Custom Chillers →
Customization Options

Customizable for Your Cooling Requirement

APT can customize this 30HP air cooled chiller according to the customer's process, installation environment, and destination country power supply.

Pump Flow and Head

Match circulation performance to loop resistance, pipe length, and required process water flow.

Evaporator Type

Review shell and tube, plate, tank coil, or project-specific evaporator direction.

Condenser Airflow

Check fan arrangement and airflow path for hotter workshops and tighter installation spaces.

Voltage and Frequency

Support export electrical standards and project-specific power requirements.

Controller and Alarm

Optional PLC, HMI, alarm, and communication logic for process integration.

Refrigerant Direction

Select refrigerant according to operating condition, project region, and engineering review.

Cabinet Layout

Cabinet structure and service access can be adapted to factory-side layout constraints.

High Ambient Design

Condenser margin and thermal protection can be reviewed for hot climate installation.

Quote Checklist

Quote Information Checklist

To recommend a suitable 30HP air cooled chiller, please prepare the following cooling requirement information before quotation review.

Application industry or cooling object

Required cooling capacity or heat load

Inlet and outlet water temperature

Water flow rate and pump head

Ambient temperature around the chiller

Power supply voltage and frequency

Installation space and ventilation condition

Water quality and evaporator material requirements

Required pump configuration or system layout

Control, alarm or communication requirements

Related Products and Resources

Explore Related APT Cooling Solutions

FAQ

FAQ About 30HP Air Cooled Chillers

What applications is a 30HP air cooled chiller suitable for?

It is commonly used for production lines, hydraulic cooling, chemical process loops, injection molding, extrusion, electroplating, die casting auxiliary cooling, thermal spray auxiliary cooling, process tanks, and general industrial process cooling.

What cooling capacity does a 30HP air cooled chiller provide?

A typical 30HP air cooled chiller provides approximately 75-90 kW cooling capacity depending on chilled water temperature, ambient temperature, compressor selection, condenser size, and pump configuration.

Does a 30HP air cooled chiller need a cooling tower?

No. An air cooled chiller rejects heat through its condenser and fan system, so it does not require a cooling tower. Good condenser airflow and installation ventilation are still important.

Can the 30HP chiller be customized for my process?

Yes. APT can customize pump pressure, evaporator type, voltage, controller, outlet direction, condenser design, high ambient configuration, and cabinet layout based on working conditions.

Can a 30HP chiller be used for hydraulic system cooling?

Yes. A 30HP air cooled chiller can support hydraulic system cooling when used with a suitable heat exchanger or process water loop selected according to oil heat load, flow rate, and temperature requirements.

Is 30HP suitable for chemical process cooling?

It can be suitable for some chemical process loops, but evaporator material, fluid compatibility, safety requirements, temperature range, and control logic should be reviewed before selection.

Is air cooled or water cooled better for a 30HP chiller?

Air cooled chillers are easier to install because they do not require a cooling tower. Water cooled models may be preferred when plant water systems are available or when indoor ventilation is limited.

Can APT customize pump flow and pump head?

Yes. Pump flow and pump head can be selected according to pipe length, process loop resistance, filter pressure loss, height difference, and required water circulation rate.

What information is needed for chiller selection?

Please provide equipment type, heat load or equipment power, target water temperature, water flow rate, pump head, ambient temperature, working hours, voltage, and installation environment.

Can APT provide high ambient temperature design?

Yes. APT can provide T3 high ambient design for hot regions, with condenser, fan, compressor, and system configuration selected according to site temperature and operating conditions.

Can the evaporator material be customized?

Yes. APT can configure shell and tube, plate, tank coil, or other evaporator directions according to process water quality, corrosion risk, flow rate, and application requirements.

How does APT test the chiller before shipment?

APT performs factory testing before shipment, including refrigeration operation, water circulation, electrical protection, controller function, alarm function, and overall performance inspection.

Final CTA

Need a 30HP Air Cooled Chiller for Your Cooling Process?

Tell us your application, heat load, required water temperature, water flow, ambient temperature, voltage, and installation conditions. APT engineers will help recommend a suitable 30HP air cooled chiller or another model if your process requires a different capacity.

滚动至顶部
Chat on WhatsApp