Home / Resources / Technical Datasheets / Air Cooled Industrial Chiller Datasheets
Air Cooled Chiller Datasheets

Air Cooled Industrial Chiller Datasheets

Technical data references for APT air cooled industrial chillers, including cooling capacity, pump flow and pressure, voltage, refrigerant, tank volume, dimensions, airflow direction, and application notes.

1–5 HP Compact Air Cooled Chillers
5–20 HP Standard Air Cooled Chillers
20–50 HP Industrial Process Chillers
50+ HP Larger Air Cooled Chiller Systems
High Ambient and Custom Air Cooled Options
Quick Answer

What Is Included in an Air Cooled Chiller Datasheet?

APT air cooled chiller datasheets provide practical technical data for initial model comparison, quotation preparation, and engineering review. They may include cooling capacity, outlet temperature range, pump flow and pressure, tank volume, refrigerant, compressor type, condenser type, voltage, dimensions, airflow direction, installation notes, and suitable applications.

  • Used for early model comparison and supplier evaluation.
  • Helps confirm whether an air cooled chiller fits the project cooling load.
  • Supports review of pump flow, pressure, voltage, and installation space.
  • Final selection should still be reviewed according to actual process conditions.
Model Data Tables

Air Cooled Chiller Model Data Tables

Use the following reference tables to compare typical air cooled industrial chiller models by capacity range. Final configuration may vary according to cooling temperature, ambient temperature, pump pressure, voltage, refrigerant, and project requirements.

Data is for initial model comparison and quotation preparation.
Final selection should be reviewed according to real heat load and operating conditions.
Pump, voltage, refrigerant, tank volume, and dimensions can be adjusted for custom projects.

1–5 HP Compact Air Cooled Chiller Datasheet Reference

Model Group Nominal HP Cooling Capacity Compressor Power Outlet Temperature Range Typical ΔT Water Flow Rate Pump Power / Pressure Tank Volume Refrigerant Power Supply Application Notes
Compact1 HPApprox. 2.5–3.0 kWApprox. 0.75 kW5–35°C standard, custom range available5°C standard referenceApprox. 8–12 L/minApprox. 0.37 kW pump, standard circulation pressureApprox. 15–25 LR410A / R407C / project-reviewed220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project1 HP air cooled chiller datasheet reference for lab instruments and small machine cooling.
Compact1.5 HPApprox. 3.8–4.5 kWApprox. 1.1 kW5–35°C standard, custom range available5°C standard referenceApprox. 12–18 L/minApprox. 0.37–0.55 kW pumpApprox. 20–35 LR410A / R407C / project-reviewed220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to projectLaser, CNC, laboratory, spindle cooling, small equipment cooling, and compact process cooling.
Compact2 HPApprox. 5.5–6.5 kWApprox. 1.5 kW5–35°C standard, custom range available5°C standard referenceApprox. 18–25 L/minApprox. 0.55 kW pumpApprox. 30–45 LR410A / R407C / project-reviewed220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to projectIce bath, laser, CNC, laboratory, and compact process cooling review.
Compact3 HPApprox. 7.5–9.0 kWApprox. 2.2 kW5–35°C standard, custom range available5°C standard referenceApprox. 25–35 L/minApprox. 0.55–0.75 kW pumpApprox. 40–60 LR410A / R407C / project-reviewed220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project3 HP air cooled process chiller technical data for CNC spindle and small process loops.
Compact5 HPApprox. 12–15 kWApprox. 3.7 kW5–35°C standard, custom range available5°C standard referenceApprox. 40–55 L/minApprox. 0.75–1.1 kW pumpApprox. 60–100 LR410A / R407C / project-reviewed220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project5 HP air cooled chiller datasheet reference for compact process cooling and CNC support.

5–20 HP Standard Air Cooled Industrial Chiller Datasheet Reference

Model Group Nominal HP Cooling Capacity Compressor Configuration Compressor Power Outlet Temperature Range Typical ΔT Water Flow Rate Pump Power / Pressure Tank Volume Refrigerant Power Supply Typical Applications
Standard5 HPApprox. 12–15 kWSingle compressor referenceApprox. 3.7 kW5–35°C standard, custom range available5°C standard referenceApprox. 40–55 L/minApprox. 0.75–1.1 kW pumpApprox. 60–100 LR410A / R407C / project-reviewedExport voltage and frequency available according to projectThermal spray auxiliary cooling, laser, machine cooling, and general process cooling.
Standard8 HPApprox. 20–24 kWSingle or dual compressor referenceApprox. 6.0 kW5–35°C standard, custom range available5°C standard referenceApprox. 65–85 L/minApprox. 1.1–1.5 kW pumpApprox. 100–150 LR410A / R407C / project-reviewedExport voltage and frequency available according to projectMachine cooling, electroplating support, and medium-duty factory cooling.
Standard10 HPApprox. 25–30 kWSingle or dual compressor referenceApprox. 7.5 kW5–35°C standard, custom range available5°C standard referenceApprox. 85–105 L/minApprox. 1.5–2.2 kW pumpApprox. 120–180 LR410A / R407C / project-reviewedExport voltage and frequency available according to project10 HP air cooled chiller datasheet direction for injection molding, laser, and equipment cooling.
Standard15 HPApprox. 38–45 kWDual compressor or project-reviewed referenceApprox. 11 kW5–35°C standard, custom range available5°C standard referenceApprox. 130–160 L/minApprox. 2.2–3.0 kW pumpApprox. 180–250 LR410A / R407C / project-reviewedExport voltage and frequency available according to projectFactory process cooling, tank cooling, electroplating, and auxiliary industrial cooling.
Standard20 HPApprox. 50–60 kWDual compressor or project-reviewed referenceApprox. 15 kW5–35°C standard, custom range available5°C standard referenceApprox. 170–210 L/minApprox. 3.0–4.0 kW pumpApprox. 250–350 LR410A / R407C / project-reviewedExport voltage and frequency available according to projectThermal spray auxiliary cooling, electroplating, injection molding, laser processing, machine cooling, and general process cooling.

20–50 HP Industrial Process Air Cooled Chiller Datasheet Reference

Model Group Nominal HP Cooling Capacity Compressor Type / Quantity Compressor Power Outlet Temperature Range Typical ΔT Water Flow Rate Pump Power / Pressure Tank Volume Condenser Airflow Direction Refrigerant Power Supply Application Notes
Industrial Process20 HPApprox. 50–60 kWScroll or semi-hermetic compressor, project reviewedApprox. 15 kW5–35°C standard, custom range available5°C standard referenceApprox. 170–210 L/minApprox. 3.0–4.0 kW pumpApprox. 250–350 LTop, side, or project-specific airflowR410A / R407C / project-reviewedExport voltage and frequency available according to destinationThermal spray cooling, die casting, coating lines, and medium industrial loops.
Industrial Process25 HPApprox. 62–75 kWScroll or semi-hermetic compressor, project reviewedApprox. 18.5 kW5–35°C standard, custom range available5°C standard referenceApprox. 210–260 L/minApprox. 4.0–5.5 kW pumpApprox. 300–450 LTop, side, or project-specific airflowR410A / R407C / project-reviewedExport voltage and frequency available according to destinationPlastic processing, thermal spray, hydraulic cooling, and process tanks.
Industrial Process30 HPApprox. 75–90 kWScroll or semi-hermetic compressor, project reviewedApprox. 22 kW5–35°C standard, custom range available5°C standard referenceApprox. 260–310 L/minApprox. 4.0–5.5 kW pumpApprox. 400–600 LTop, side, or project-specific airflowR410A / R407C / project-reviewedExport voltage and frequency available according to destination30 HP air cooled chiller datasheet reference for production equipment and chemical process loops.
Industrial Process40 HPApprox. 100–120 kWScroll or semi-hermetic compressor, project reviewedApprox. 30 kW5–35°C standard, custom range available5°C standard referenceApprox. 340–420 L/minApprox. 5.5–7.5 kW pumpApprox. 500–800 LTop, side, or project-specific airflowR410A / R407C / project-reviewedExport voltage and frequency available according to destinationHigh ambient, multi-station equipment cooling, die casting, and continuous factory operation.
Industrial Process50 HPApprox. 125–150 kWScroll or semi-hermetic compressor, project reviewedApprox. 37 kW5–35°C standard, custom range available5°C standard referenceApprox. 430–520 L/minApprox. 7.5 kW pump or higher-pressure pump by piping lossApprox. 600–1000 LTop, side, or project-specific airflowR410A / R407C / project-reviewedExport voltage and frequency available according to destinationThermal spray cooling, die casting, coating lines, multi-station equipment cooling, and continuous factory process cooling.

50+ HP Large Air Cooled Chiller System Datasheet Reference

Capacity Group Nominal HP Cooling Capacity Compressor Configuration Temperature Range Water Flow Rate Pump Configuration Tank / Buffer Option Condenser Design Power Supply Installation Notes Custom Options
Large System50 HPApprox. 125–150 kWMulti-compressor or project-reviewed configuration5–35°C standard, custom range availableApprox. 430–520 L/minStandard or high-pressure pump according to piping lossBuilt-in or external buffer tank reviewHigh airflow air cooled condenserExport voltage and frequency availableRequires ventilation, service access, and airflow clearance review.High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface.
Large System60 HPApprox. 150–180 kWMulti-compressor or project-reviewed configuration5–35°C standard, custom range availableApprox. 520–620 L/minSingle or dual pump configuration availableBuilt-in or external buffer tank reviewHigh airflow air cooled condenserExport voltage and frequency availableReviewed for factory process cooling and larger industrial cooling loops.High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface.
Large System80 HPApprox. 200–240 kWMulti-compressor or project-reviewed configuration5–35°C standard, custom range availableApprox. 690–830 L/minPump and buffer tank sized by flow rate and pipe resistanceBuilt-in or external buffer tank reviewHigh airflow air cooled condenserExport voltage and frequency availableReviewed for multi-point equipment cooling and production line operation.High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface.
Large System100 HPApprox. 250–300 kWMulti-compressor or project-reviewed configuration5–35°C standard, custom range availableApprox. 860–1040 L/minProject-specific pump, tank, condenser, and electrical designBuilt-in or external buffer tank reviewHigh airflow air cooled condenserExport voltage and frequency availableRequires project-level airflow, electrical, transport, and installation review.High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface.
Large SystemProject-specific300+ kW by engineering reviewCustom compressor and refrigeration configurationProject-definedReviewed according to heat load, outlet temperature, ambient temperature, and installation conditionSingle, dual, or external pump stationBuilt-in or external buffer tank reviewCustom condenser designExport voltage and frequency availableFor large industrial process cooling where standard packaged models need engineering review.High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface.

How to Read the Datasheet Tables

  • Cooling capacity is affected by chilled water outlet temperature and ambient temperature.
  • Water flow rate is usually calculated according to heat load and temperature difference.
  • Pump pressure must be checked according to pipe distance, height difference, valve loss, and equipment pressure loss.
  • Tank volume, pump pressure, voltage, condenser structure, and dimensions may vary by project.
  • Dimensions and layout may vary according to tank, pump, condenser, and custom structure.
  • Final datasheet should be confirmed after reviewing real working conditions.
Datasheet Group Notes

Datasheet Group Notes

Use these notes to choose the right air cooled chiller datasheet group before requesting detailed air cooled industrial chiller specifications. The model data tables above remain the main reference for early comparison.

Datasheet Group Selection Direction Main Data Included Best For CTA
Compact Air Cooled Chiller Datasheets 1–5 HP compact machine-side cooling Cooling capacity, compact dimensions, pump data, tank volume, voltage, refrigerant, and machine-side cooling notes. Laser, CNC, laboratory, small equipment cooling, and limited-space installation. Request Compact Chiller Datasheet →
Standard Air Cooled Chiller Datasheets 5–20 HP standard process cooling Model data, cooling capacity, pump flow and pressure, tank volume, voltage, control options, and installation notes. General factory process cooling, thermal spray auxiliary cooling, electroplating, injection molding, and machine cooling. Request Standard Chiller Datasheet →
Medium Capacity Air Cooled Chiller Datasheets 20–50 HP industrial process cooling Larger cooling capacity, compressor configuration, condenser airflow, pump options, electrical data, and dimensions. Industrial process cooling, multi-station equipment, die casting, coating lines, and continuous factory operation. Request Medium Capacity Datasheet →
Large Air Cooled Chiller Datasheets 50+ HP High-capacity air cooled configuration, refrigeration system data, installation requirements, airflow direction, and voltage options. Large process cooling systems, centralized cooling, and projects without condenser water. Request Large Chiller Datasheet →
High Ambient Air Cooled Chiller Datasheets Project-specific High ambient condenser design, operating condition, temperature reference, electrical configuration, and installation notes. Hot workshops, outdoor or semi-outdoor installation, and high ambient factory conditions. Submit High Ambient Requirements →
Technical Parameters

Technical Parameters Explained

Parameter What It Means Selection Note
Cooling CapacityReference HP, kW, kcal/h, model group, and industrial chiller cooling capacity table data.Compare against real heat load, outlet temperature, ambient temperature, and operating duty.
Outlet Temperature RangeStandard chilled water outlet range and optional low-temperature or precision temperature range.Confirm whether the air cooled process chiller technical data fits the required process temperature.
Pump Flow and PressureStandard pump flow, pump head, pressure reference, and optional pump configuration.Review pipe length, filters, heat exchangers, machine resistance, and required circulation flow.
Tank VolumeStandard tank capacity or optional buffer tank volume for the cooling loop.Affects temperature stability, system buffer capacity, and short-cycle protection.
Refrigeration SystemCompressor type, condenser type, evaporator type, refrigerant, and control logic.Shows the core cooling structure before confirming final air cooled industrial chiller specifications.
Air Cooled CondenserCondenser type, airflow direction, ventilation clearance, and ambient condition notes.Important for installation space, heat rejection, hot-air recirculation, and high ambient review.
Electrical DataVoltage, phase, frequency, control panel, protection functions, and export configuration notes.Supports site electrical confirmation and quotation discussion for different destination markets.
Dimensions and WeightMachine size, footprint, service access, approximate weight, and packaging direction.Helps confirm installation space, transport planning, and maintenance access.
Application NotesSuitable process, ambient condition, fluid reference, installation condition, and project limits.Connects datasheet data to real factory operation before requesting final model confirmation.
Capacity Range

Air Cooled Chiller Capacity Range Overview

1–5 HP Air Cooled Chillers

Compact air cooled chillers for small equipment cooling, laboratory systems, laser equipment, CNC machines, and limited-space installation.

Related Page →

5–20 HP Air Cooled Chillers

Standard air cooled industrial chillers for general process cooling, machine cooling, and factory-side temperature control.

Related Page →

20–50 HP Air Cooled Chillers

Medium-capacity air cooled chillers for industrial processes requiring higher cooling capacity, stronger pump options, and continuous operation.

Related Page →

50+ HP Air Cooled Chillers

Larger air cooled chiller systems for process cooling projects where condenser water is unavailable or not preferred.

Related Page →

High Ambient Air Cooled Chillers

Custom air cooled chillers reviewed for hot workshops, outdoor installation, high ambient temperature, and demanding condenser ventilation conditions.

Related Page →

Request Process

Information Needed Before Requesting an Air Cooled Chiller Datasheet

  • Cooling application or equipment type
  • Required cooling capacity or heat load
  • Target chilled water or process fluid temperature
  • Inlet and outlet temperature if available
  • Process fluid type
  • Pump flow and pressure requirements
  • Tank volume requirement if any
  • Pipe distance or pressure loss if available
  • Ambient temperature
  • Indoor, outdoor, or semi-outdoor installation
  • Ventilation and airflow condition
  • Voltage, phase, and frequency
  • Installation space limitation
  • Operating hours or duty cycle
  • Special requirements such as high ambient, vertical structure, mobile frame, or OEM interface
FAQ

Air Cooled Industrial Chiller Datasheets FAQ

What is an air cooled industrial chiller datasheet?

An air cooled industrial chiller datasheet is a technical reference that summarizes cooling capacity, temperature range, pump data, tank volume, refrigerant, voltage, dimensions, condenser airflow, and application notes.

How should I compare cooling capacity in the datasheet table?

Use the industrial chiller cooling capacity table as an initial comparison reference. Cooling capacity should be compared with real heat load, target outlet temperature, ambient temperature, and operating duty before final selection.

Why does cooling capacity change with chilled water temperature?

Lower outlet temperature usually reduces available cooling capacity. Datasheet review should confirm the required temperature point before final model selection.

How should I read the water flow rate in the datasheet table?

Water flow rate is a reference value based on heat load and temperature difference. The final flow rate should match the equipment requirement and pipe system design.

Can pump flow and pressure be customized?

Yes. Pump flow and pressure can be adjusted according to pipe distance, pressure loss, equipment resistance, and required circulation condition.

Are the cooling capacity values in the table final selection data?

No. The values are reference data for initial comparison. Final cooling capacity should be checked according to heat load, outlet temperature, ambient temperature, and operating conditions.

Can I request a 1 HP, 5 HP, 10 HP, 20 HP, 30 HP, or 50 HP datasheet?

Yes. APT can provide air cooled chiller datasheet references for common model groups such as 1 HP, 5 HP, 10 HP, 20 HP, 30 HP, 50 HP, and project-specific configurations.

Do air cooled chiller datasheets include voltage options?

Datasheets may include common voltage, phase, and frequency options. Export projects should confirm local electrical conditions before final quotation.

What should I provide before requesting an air cooled chiller datasheet?

Please provide the cooling application, required capacity or heat load, target temperature, process fluid, pump requirements, voltage, ambient temperature, and installation condition.

Can APT provide a final datasheet for my project?

Yes. APT can prepare a project-specific datasheet after reviewing the cooling application, required capacity, target temperature, fluid, pump requirement, voltage, ambient temperature, and installation condition.

Next Step

Request Air Cooled Industrial Chiller Datasheets

Send your cooling application, required capacity, target temperature, process fluid, pump requirements, voltage, ambient temperature, and installation condition. APT can help provide suitable air cooled chiller datasheets or recommend a starting configuration for your project.

Scroll to Top
Chat on WhatsApp