Air Cooled Industrial Chiller Datasheets
Technical data references for APT air cooled industrial chillers, including cooling capacity, pump flow and pressure, voltage, refrigerant, tank volume, dimensions, airflow direction, and application notes.
What Is Included in an Air Cooled Chiller Datasheet?
APT air cooled chiller datasheets provide practical technical data for initial model comparison, quotation preparation, and engineering review. They may include cooling capacity, outlet temperature range, pump flow and pressure, tank volume, refrigerant, compressor type, condenser type, voltage, dimensions, airflow direction, installation notes, and suitable applications.
- Used for early model comparison and supplier evaluation.
- Helps confirm whether an air cooled chiller fits the project cooling load.
- Supports review of pump flow, pressure, voltage, and installation space.
- Final selection should still be reviewed according to actual process conditions.
Air Cooled Chiller Model Data Tables
Use the following reference tables to compare typical air cooled industrial chiller models by capacity range. Final configuration may vary according to cooling temperature, ambient temperature, pump pressure, voltage, refrigerant, and project requirements.
1–5 HP Compact Air Cooled Chiller Datasheet Reference
| Model Group | Nominal HP | Cooling Capacity | Compressor Power | Outlet Temperature Range | Typical ΔT | Water Flow Rate | Pump Power / Pressure | Tank Volume | Refrigerant | Power Supply | Application Notes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Compact | 1 HP | Approx. 2.5–3.0 kW | Approx. 0.75 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 8–12 L/min | Approx. 0.37 kW pump, standard circulation pressure | Approx. 15–25 L | R410A / R407C / project-reviewed | 220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project | 1 HP air cooled chiller datasheet reference for lab instruments and small machine cooling. |
| Compact | 1.5 HP | Approx. 3.8–4.5 kW | Approx. 1.1 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 12–18 L/min | Approx. 0.37–0.55 kW pump | Approx. 20–35 L | R410A / R407C / project-reviewed | 220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project | Laser, CNC, laboratory, spindle cooling, small equipment cooling, and compact process cooling. |
| Compact | 2 HP | Approx. 5.5–6.5 kW | Approx. 1.5 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 18–25 L/min | Approx. 0.55 kW pump | Approx. 30–45 L | R410A / R407C / project-reviewed | 220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project | Ice bath, laser, CNC, laboratory, and compact process cooling review. |
| Compact | 3 HP | Approx. 7.5–9.0 kW | Approx. 2.2 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 25–35 L/min | Approx. 0.55–0.75 kW pump | Approx. 40–60 L | R410A / R407C / project-reviewed | 220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project | 3 HP air cooled process chiller technical data for CNC spindle and small process loops. |
| Compact | 5 HP | Approx. 12–15 kW | Approx. 3.7 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 40–55 L/min | Approx. 0.75–1.1 kW pump | Approx. 60–100 L | R410A / R407C / project-reviewed | 220V/1Ph/50Hz, 380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz available according to project | 5 HP air cooled chiller datasheet reference for compact process cooling and CNC support. |
5–20 HP Standard Air Cooled Industrial Chiller Datasheet Reference
| Model Group | Nominal HP | Cooling Capacity | Compressor Configuration | Compressor Power | Outlet Temperature Range | Typical ΔT | Water Flow Rate | Pump Power / Pressure | Tank Volume | Refrigerant | Power Supply | Typical Applications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Standard | 5 HP | Approx. 12–15 kW | Single compressor reference | Approx. 3.7 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 40–55 L/min | Approx. 0.75–1.1 kW pump | Approx. 60–100 L | R410A / R407C / project-reviewed | Export voltage and frequency available according to project | Thermal spray auxiliary cooling, laser, machine cooling, and general process cooling. |
| Standard | 8 HP | Approx. 20–24 kW | Single or dual compressor reference | Approx. 6.0 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 65–85 L/min | Approx. 1.1–1.5 kW pump | Approx. 100–150 L | R410A / R407C / project-reviewed | Export voltage and frequency available according to project | Machine cooling, electroplating support, and medium-duty factory cooling. |
| Standard | 10 HP | Approx. 25–30 kW | Single or dual compressor reference | Approx. 7.5 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 85–105 L/min | Approx. 1.5–2.2 kW pump | Approx. 120–180 L | R410A / R407C / project-reviewed | Export voltage and frequency available according to project | 10 HP air cooled chiller datasheet direction for injection molding, laser, and equipment cooling. |
| Standard | 15 HP | Approx. 38–45 kW | Dual compressor or project-reviewed reference | Approx. 11 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 130–160 L/min | Approx. 2.2–3.0 kW pump | Approx. 180–250 L | R410A / R407C / project-reviewed | Export voltage and frequency available according to project | Factory process cooling, tank cooling, electroplating, and auxiliary industrial cooling. |
| Standard | 20 HP | Approx. 50–60 kW | Dual compressor or project-reviewed reference | Approx. 15 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 170–210 L/min | Approx. 3.0–4.0 kW pump | Approx. 250–350 L | R410A / R407C / project-reviewed | Export voltage and frequency available according to project | Thermal spray auxiliary cooling, electroplating, injection molding, laser processing, machine cooling, and general process cooling. |
20–50 HP Industrial Process Air Cooled Chiller Datasheet Reference
| Model Group | Nominal HP | Cooling Capacity | Compressor Type / Quantity | Compressor Power | Outlet Temperature Range | Typical ΔT | Water Flow Rate | Pump Power / Pressure | Tank Volume | Condenser Airflow Direction | Refrigerant | Power Supply | Application Notes |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Industrial Process | 20 HP | Approx. 50–60 kW | Scroll or semi-hermetic compressor, project reviewed | Approx. 15 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 170–210 L/min | Approx. 3.0–4.0 kW pump | Approx. 250–350 L | Top, side, or project-specific airflow | R410A / R407C / project-reviewed | Export voltage and frequency available according to destination | Thermal spray cooling, die casting, coating lines, and medium industrial loops. |
| Industrial Process | 25 HP | Approx. 62–75 kW | Scroll or semi-hermetic compressor, project reviewed | Approx. 18.5 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 210–260 L/min | Approx. 4.0–5.5 kW pump | Approx. 300–450 L | Top, side, or project-specific airflow | R410A / R407C / project-reviewed | Export voltage and frequency available according to destination | Plastic processing, thermal spray, hydraulic cooling, and process tanks. |
| Industrial Process | 30 HP | Approx. 75–90 kW | Scroll or semi-hermetic compressor, project reviewed | Approx. 22 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 260–310 L/min | Approx. 4.0–5.5 kW pump | Approx. 400–600 L | Top, side, or project-specific airflow | R410A / R407C / project-reviewed | Export voltage and frequency available according to destination | 30 HP air cooled chiller datasheet reference for production equipment and chemical process loops. |
| Industrial Process | 40 HP | Approx. 100–120 kW | Scroll or semi-hermetic compressor, project reviewed | Approx. 30 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 340–420 L/min | Approx. 5.5–7.5 kW pump | Approx. 500–800 L | Top, side, or project-specific airflow | R410A / R407C / project-reviewed | Export voltage and frequency available according to destination | High ambient, multi-station equipment cooling, die casting, and continuous factory operation. |
| Industrial Process | 50 HP | Approx. 125–150 kW | Scroll or semi-hermetic compressor, project reviewed | Approx. 37 kW | 5–35°C standard, custom range available | 5°C standard reference | Approx. 430–520 L/min | Approx. 7.5 kW pump or higher-pressure pump by piping loss | Approx. 600–1000 L | Top, side, or project-specific airflow | R410A / R407C / project-reviewed | Export voltage and frequency available according to destination | Thermal spray cooling, die casting, coating lines, multi-station equipment cooling, and continuous factory process cooling. |
50+ HP Large Air Cooled Chiller System Datasheet Reference
| Capacity Group | Nominal HP | Cooling Capacity | Compressor Configuration | Temperature Range | Water Flow Rate | Pump Configuration | Tank / Buffer Option | Condenser Design | Power Supply | Installation Notes | Custom Options |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Large System | 50 HP | Approx. 125–150 kW | Multi-compressor or project-reviewed configuration | 5–35°C standard, custom range available | Approx. 430–520 L/min | Standard or high-pressure pump according to piping loss | Built-in or external buffer tank review | High airflow air cooled condenser | Export voltage and frequency available | Requires ventilation, service access, and airflow clearance review. | High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface. |
| Large System | 60 HP | Approx. 150–180 kW | Multi-compressor or project-reviewed configuration | 5–35°C standard, custom range available | Approx. 520–620 L/min | Single or dual pump configuration available | Built-in or external buffer tank review | High airflow air cooled condenser | Export voltage and frequency available | Reviewed for factory process cooling and larger industrial cooling loops. | High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface. |
| Large System | 80 HP | Approx. 200–240 kW | Multi-compressor or project-reviewed configuration | 5–35°C standard, custom range available | Approx. 690–830 L/min | Pump and buffer tank sized by flow rate and pipe resistance | Built-in or external buffer tank review | High airflow air cooled condenser | Export voltage and frequency available | Reviewed for multi-point equipment cooling and production line operation. | High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface. |
| Large System | 100 HP | Approx. 250–300 kW | Multi-compressor or project-reviewed configuration | 5–35°C standard, custom range available | Approx. 860–1040 L/min | Project-specific pump, tank, condenser, and electrical design | Built-in or external buffer tank review | High airflow air cooled condenser | Export voltage and frequency available | Requires project-level airflow, electrical, transport, and installation review. | High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface. |
| Large System | Project-specific | 300+ kW by engineering review | Custom compressor and refrigeration configuration | Project-defined | Reviewed according to heat load, outlet temperature, ambient temperature, and installation condition | Single, dual, or external pump station | Built-in or external buffer tank review | Custom condenser design | Export voltage and frequency available | For large industrial process cooling where standard packaged models need engineering review. | High ambient condenser, stainless steel tank, stronger pump, remote control, special voltage, outdoor structure, OEM interface. |
How to Read the Datasheet Tables
- Cooling capacity is affected by chilled water outlet temperature and ambient temperature.
- Water flow rate is usually calculated according to heat load and temperature difference.
- Pump pressure must be checked according to pipe distance, height difference, valve loss, and equipment pressure loss.
- Tank volume, pump pressure, voltage, condenser structure, and dimensions may vary by project.
- Dimensions and layout may vary according to tank, pump, condenser, and custom structure.
- Final datasheet should be confirmed after reviewing real working conditions.
Datasheet Group Notes
Use these notes to choose the right air cooled chiller datasheet group before requesting detailed air cooled industrial chiller specifications. The model data tables above remain the main reference for early comparison.
| Datasheet Group | Selection Direction | Main Data Included | Best For | CTA |
|---|---|---|---|---|
| Compact Air Cooled Chiller Datasheets | 1–5 HP compact machine-side cooling | Cooling capacity, compact dimensions, pump data, tank volume, voltage, refrigerant, and machine-side cooling notes. | Laser, CNC, laboratory, small equipment cooling, and limited-space installation. | Request Compact Chiller Datasheet → |
| Standard Air Cooled Chiller Datasheets | 5–20 HP standard process cooling | Model data, cooling capacity, pump flow and pressure, tank volume, voltage, control options, and installation notes. | General factory process cooling, thermal spray auxiliary cooling, electroplating, injection molding, and machine cooling. | Request Standard Chiller Datasheet → |
| Medium Capacity Air Cooled Chiller Datasheets | 20–50 HP industrial process cooling | Larger cooling capacity, compressor configuration, condenser airflow, pump options, electrical data, and dimensions. | Industrial process cooling, multi-station equipment, die casting, coating lines, and continuous factory operation. | Request Medium Capacity Datasheet → |
| Large Air Cooled Chiller Datasheets | 50+ HP | High-capacity air cooled configuration, refrigeration system data, installation requirements, airflow direction, and voltage options. | Large process cooling systems, centralized cooling, and projects without condenser water. | Request Large Chiller Datasheet → |
| High Ambient Air Cooled Chiller Datasheets | Project-specific | High ambient condenser design, operating condition, temperature reference, electrical configuration, and installation notes. | Hot workshops, outdoor or semi-outdoor installation, and high ambient factory conditions. | Submit High Ambient Requirements → |
Technical Parameters Explained
| Parameter | What It Means | Selection Note |
|---|---|---|
| Cooling Capacity | Reference HP, kW, kcal/h, model group, and industrial chiller cooling capacity table data. | Compare against real heat load, outlet temperature, ambient temperature, and operating duty. |
| Outlet Temperature Range | Standard chilled water outlet range and optional low-temperature or precision temperature range. | Confirm whether the air cooled process chiller technical data fits the required process temperature. |
| Pump Flow and Pressure | Standard pump flow, pump head, pressure reference, and optional pump configuration. | Review pipe length, filters, heat exchangers, machine resistance, and required circulation flow. |
| Tank Volume | Standard tank capacity or optional buffer tank volume for the cooling loop. | Affects temperature stability, system buffer capacity, and short-cycle protection. |
| Refrigeration System | Compressor type, condenser type, evaporator type, refrigerant, and control logic. | Shows the core cooling structure before confirming final air cooled industrial chiller specifications. |
| Air Cooled Condenser | Condenser type, airflow direction, ventilation clearance, and ambient condition notes. | Important for installation space, heat rejection, hot-air recirculation, and high ambient review. |
| Electrical Data | Voltage, phase, frequency, control panel, protection functions, and export configuration notes. | Supports site electrical confirmation and quotation discussion for different destination markets. |
| Dimensions and Weight | Machine size, footprint, service access, approximate weight, and packaging direction. | Helps confirm installation space, transport planning, and maintenance access. |
| Application Notes | Suitable process, ambient condition, fluid reference, installation condition, and project limits. | Connects datasheet data to real factory operation before requesting final model confirmation. |
Air Cooled Chiller Capacity Range Overview
1–5 HP Air Cooled Chillers
Compact air cooled chillers for small equipment cooling, laboratory systems, laser equipment, CNC machines, and limited-space installation.
5–20 HP Air Cooled Chillers
Standard air cooled industrial chillers for general process cooling, machine cooling, and factory-side temperature control.
20–50 HP Air Cooled Chillers
Medium-capacity air cooled chillers for industrial processes requiring higher cooling capacity, stronger pump options, and continuous operation.
50+ HP Air Cooled Chillers
Larger air cooled chiller systems for process cooling projects where condenser water is unavailable or not preferred.
High Ambient Air Cooled Chillers
Custom air cooled chillers reviewed for hot workshops, outdoor installation, high ambient temperature, and demanding condenser ventilation conditions.
Typical Applications for Air Cooled Chiller Datasheets
Thermal Spray Cooling
Air cooled chillers can support cooling for plasma spray, HVOF systems, power supply, torch, and auxiliary equipment where stable cooling water is required.
View Application →Laser Cooling
Compact and standard air cooled chillers are commonly reviewed for laser equipment cooling, machine-side cooling, and temperature stability.
View Application →Injection Molding Cooling
Air cooled chillers can be used for mold cooling, hydraulic cooling, and auxiliary process cooling when condenser water is not available.
View Application →Electroplating Cooling
Air cooled chillers may support plating bath temperature control and process water cooling according to tank size and heat load.
View Application →CNC Machine Cooling
Compact air cooled chillers can support spindle cooling, cutting fluid cooling, and machine-side temperature control.
View Application →Laboratory Cooling
Small air cooled chillers can support laboratory instruments, test systems, and controlled cooling water supply.
View Application →Information Needed Before Requesting an Air Cooled Chiller Datasheet
- Cooling application or equipment type
- Required cooling capacity or heat load
- Target chilled water or process fluid temperature
- Inlet and outlet temperature if available
- Process fluid type
- Pump flow and pressure requirements
- Tank volume requirement if any
- Pipe distance or pressure loss if available
- Ambient temperature
- Indoor, outdoor, or semi-outdoor installation
- Ventilation and airflow condition
- Voltage, phase, and frequency
- Installation space limitation
- Operating hours or duty cycle
- Special requirements such as high ambient, vertical structure, mobile frame, or OEM interface
Related Technical Datasheet Pages
Technical Datasheets
Return to the complete APT technical datasheet center.
Open Page →Water Cooled Industrial Chiller Datasheets
Review water cooled chiller technical data for continuous-duty and larger capacity cooling.
Open Page →Custom Industrial Chiller Datasheets
Review custom chiller data for high ambient, explosion-proof, stainless steel, vertical, mobile, and OEM projects.
Open Page →Parts & Heat Exchanger Datasheets
Review chiller parts, heat exchanger, pump, compressor, condenser, and evaporator reference data.
Open Page →Export Voltage Configuration Reference
Review common export voltage and frequency configurations for industrial chiller projects.
Open Page →Air Cooled Industrial Chiller Datasheets FAQ
What is an air cooled industrial chiller datasheet?
An air cooled industrial chiller datasheet is a technical reference that summarizes cooling capacity, temperature range, pump data, tank volume, refrigerant, voltage, dimensions, condenser airflow, and application notes.
How should I compare cooling capacity in the datasheet table?
Use the industrial chiller cooling capacity table as an initial comparison reference. Cooling capacity should be compared with real heat load, target outlet temperature, ambient temperature, and operating duty before final selection.
Why does cooling capacity change with chilled water temperature?
Lower outlet temperature usually reduces available cooling capacity. Datasheet review should confirm the required temperature point before final model selection.
How should I read the water flow rate in the datasheet table?
Water flow rate is a reference value based on heat load and temperature difference. The final flow rate should match the equipment requirement and pipe system design.
Can pump flow and pressure be customized?
Yes. Pump flow and pressure can be adjusted according to pipe distance, pressure loss, equipment resistance, and required circulation condition.
Are the cooling capacity values in the table final selection data?
No. The values are reference data for initial comparison. Final cooling capacity should be checked according to heat load, outlet temperature, ambient temperature, and operating conditions.
Can I request a 1 HP, 5 HP, 10 HP, 20 HP, 30 HP, or 50 HP datasheet?
Yes. APT can provide air cooled chiller datasheet references for common model groups such as 1 HP, 5 HP, 10 HP, 20 HP, 30 HP, 50 HP, and project-specific configurations.
Do air cooled chiller datasheets include voltage options?
Datasheets may include common voltage, phase, and frequency options. Export projects should confirm local electrical conditions before final quotation.
What should I provide before requesting an air cooled chiller datasheet?
Please provide the cooling application, required capacity or heat load, target temperature, process fluid, pump requirements, voltage, ambient temperature, and installation condition.
Can APT provide a final datasheet for my project?
Yes. APT can prepare a project-specific datasheet after reviewing the cooling application, required capacity, target temperature, fluid, pump requirement, voltage, ambient temperature, and installation condition.
Request Air Cooled Industrial Chiller Datasheets
Send your cooling application, required capacity, target temperature, process fluid, pump requirements, voltage, ambient temperature, and installation condition. APT can help provide suitable air cooled chiller datasheets or recommend a starting configuration for your project.