Home / Resources / Technical Datasheets / Water Cooled Industrial Chiller Datasheets
Water Cooled Chiller Technical Data

Water Cooled Industrial Chiller Datasheets

Review reference specifications for water cooled industrial chillers used in continuous process cooling, large-capacity equipment cooling, central cooling systems, and factory production lines.

Water cooled chiller specification reference
Cooling capacity, water flow, compressor, condenser, and power data
Suitable for large heat load and continuous industrial operation
Final datasheet available after project review
Water Cooled Datasheet Preview
Capacity
5–100+ HP
Condenser
Water cooled
Flow Data
CHW + CW
Final Review
Project data
Quick Answer

Water cooled industrial chiller datasheets should be reviewed according to cooling capacity, chilled water temperature, condenser water inlet and outlet temperature, water flow rate, compressor configuration, pump requirement, voltage, and installation conditions. Compared with air cooled chillers, water cooled chillers are usually selected for larger capacity, continuous operation, lower condenser pressure, and factory systems where cooling towers or condenser water circuits are available.

  • Datasheet PurposeWater cooled chiller datasheet and engineering data reference.
  • Technical DataCooling capacity, chilled water flow, condenser water flow, compressor, pump, voltage.
  • Before QuotationCompare industrial water cooled chiller technical data before requesting final selection.
Model Data Tables

Water Cooled Chiller Model Data Tables

Use the following reference tables to compare typical water cooled industrial chiller models by capacity range. Final configuration may vary according to chilled water temperature, condenser water condition, pump pressure, voltage, refrigerant, compressor configuration, and project requirements.

Initial Comparison

Data is for initial model comparison and quotation preparation.

Final Review

Final selection should be reviewed according to real heat load and operating conditions.

Temperature Effect

Cooling capacity is affected by chilled water outlet temperature and condenser water inlet temperature.

Custom Items

Pump, voltage, refrigerant, evaporator, condenser, and control system can be adjusted for custom projects.

5–20 HP Water Cooled Industrial Chiller Datasheet Reference

Reference values for small and medium process cooling
Model GroupNominal HPCooling CapacityCompressor PowerChilled Water Outlet RangeTypical Chilled Water ΔTChilled Water Flow RateCondenser Water Flow RateCondenser Water In / OutEvaporator TypeCondenser TypeRefrigerantPower SupplyApplication Notes
Standard Water Cooled5 HPApprox. 13–16 kWApprox. 3.7 kW5–35°C standard, custom range available5°C referenceApprox. 45–55 L/minApprox. 55–70 L/min30°C / 35°C referenceStainless steel plate heat exchanger or shell-and-tube optionWater cooled shell-and-tube condenserR410A / R407C / project-reviewed380V/3Ph/50Hz, 220V/3Ph/60Hz, 460V/3Ph/60Hz availableMachine cooling, electroplating, laser, small process cooling.
Standard Water Cooled8 HPApprox. 21–25 kWApprox. 6.0 kW5–35°C standard, custom range available5°C referenceApprox. 70–90 L/minApprox. 90–110 L/min30°C / 35°C referencePlate heat exchanger or shell-and-tube optionWater cooled shell-and-tube condenserR410A / R407C / project-reviewedExport voltage and frequency availableSmall production equipment, laboratory process loop, plating bath cooling.
Standard Water Cooled10 HPApprox. 26–32 kWApprox. 7.5 kW5–35°C standard, custom range available5°C referenceApprox. 90–110 L/minApprox. 110–135 L/min30°C / 35°C referencePlate heat exchanger or shell-and-tube optionWater cooled shell-and-tube condenserR410A / R407C / project-reviewedExport voltage and frequency availableInjection molding, laser, CNC, process tank cooling.
Standard Water Cooled15 HPApprox. 40–48 kWApprox. 11 kW5–35°C standard, custom range available5°C referenceApprox. 135–165 L/minApprox. 165–200 L/min30°C / 35°C referencePlate heat exchanger or shell-and-tube optionWater cooled shell-and-tube condenserR410A / R407C / project-reviewedExport voltage and frequency availableMedium process cooling, plating, hydraulic systems, factory equipment.
Standard Water Cooled20 HPApprox. 52–62 kWApprox. 15 kW5–35°C standard, custom range available5°C referenceApprox. 180–215 L/minApprox. 215–260 L/min30°C / 35°C referencePlate heat exchanger or shell-and-tube optionWater cooled shell-and-tube condenserR410A / R407C / project-reviewedExport voltage and frequency availableProduction equipment, thermal spray, die casting, chemical process cooling.

20–50 HP Industrial Water Cooled Chiller Datasheet Reference

Reference values for continuous industrial process cooling
Model GroupNominal HPCooling CapacityCompressor Type / QuantityCompressor PowerChilled Water Outlet RangeTypical ΔTChilled Water Flow RateCondenser Water Flow RateCondenser Water In / OutPump ConfigurationEvaporatorCondenserPower SupplyTypical Applications
Industrial Water Cooled20 HPApprox. 52–62 kWScroll or semi-hermetic compressor, project-reviewedApprox. 15 kW5–35°C standard, custom range available5°C referenceApprox. 180–215 L/minApprox. 215–260 L/min30°C / 35°C referenceStandard circulation pump or pump sized by pipe resistancePlate or shell-and-tube evaporatorWater cooled shell-and-tube condenserExport voltage and frequency availableThermal spray, die casting, electroplating lines, chemical process cooling.
Industrial Water Cooled25 HPApprox. 65–78 kWScroll or semi-hermetic compressor, project-reviewedApprox. 18.5 kW5–35°C standard, custom range available5°C referenceApprox. 225–270 L/minApprox. 270–325 L/min30°C / 35°C referenceStandard or high-pressure pump according to piping lossPlate or shell-and-tube evaporatorWater cooled shell-and-tube condenserExport voltage and frequency availableProduction equipment, plastic extrusion, process tanks.
Industrial Water Cooled30 HPApprox. 78–95 kWScroll or semi-hermetic compressor, project-reviewedApprox. 22 kW5–35°C standard, custom range available5°C referenceApprox. 270–330 L/minApprox. 330–395 L/min30°C / 35°C referencePump selected by flow rate and headPlate or shell-and-tube evaporatorWater cooled shell-and-tube condenserExport voltage and frequency availableCentralized factory equipment cooling and continuous process loops.
Industrial Water Cooled40 HPApprox. 105–125 kWSingle or multiple compressor configuration availableApprox. 30 kW5–35°C standard, custom range available5°C referenceApprox. 360–430 L/minApprox. 430–520 L/min30°C / 35°C referencePump selected by pipe distance and pressure lossShell-and-tube evaporator or project-reviewed exchangerWater cooled shell-and-tube condenserExport voltage and frequency availableLarge equipment cooling, die casting, chemical process cooling.
Industrial Water Cooled50 HPApprox. 130–155 kWSingle or multiple compressor configuration availableApprox. 37 kW5–35°C standard, custom range available5°C referenceApprox. 450–535 L/minApprox. 535–645 L/min30°C / 35°C referenceStandard or external pump station by project reviewShell-and-tube evaporator or project-reviewed exchangerWater cooled shell-and-tube condenserExport voltage and frequency availableCentralized factory equipment cooling and continuous industrial cooling.

50+ HP Large Water Cooled Chiller System Datasheet Reference

Reference values for central cooling and large-capacity projects
Capacity GroupNominal HPCooling CapacityCompressor ConfigurationChilled Water Temperature RangeChilled Water Flow RateCondenser Water Flow RateCondenser Water ConditionEvaporator OptionPump SystemControl SystemPower SupplyInstallation NotesCustom Options
Large System50 HPApprox. 130–155 kWSingle or multiple compressor configuration available5–35°C standard, custom range availableApprox. 450–535 L/minApprox. 535–645 L/min30°C / 35°C reference or project-confirmedShell-and-tube evaporator or plate heat exchangerBuilt-in or external pump stationDigital controller or PLC optionExport voltage and frequency availableRequires condenser water circuit and service access review.Dual pump, buffer tank, PLC, Modbus, stainless wetted parts.
Large System60 HPApprox. 155–185 kWMultiple compressor configuration available5–35°C standard, custom range availableApprox. 535–640 L/minApprox. 640–770 L/min30°C / 35°C reference or project-confirmedShell-and-tube evaporator or project-reviewed exchangerExternal pump station optionalDigital controller or PLC optionExport voltage and frequency availableReviewed for factory chilled-water loop and cooling tower condition.Dual pump, stronger pump, larger buffer tank, communication interface.
Large System80 HPApprox. 210–250 kWMultiple compressor configuration available5–35°C standard, custom range availableApprox. 720–860 L/minApprox. 860–1030 L/min30°C / 35°C reference or project-confirmedShell-and-tube evaporator or project-reviewed exchangerExternal pump station commonly reviewedPLC, HMI, Modbus, alarm output optionalExport voltage and frequency availableReviewed for multi-point process cooling and pipe system pressure loss.Skid-mounted structure, PLC control, special voltage, central cooling design.
Large System100 HPApprox. 260–310 kWMultiple compressor configuration available5–35°C standard, custom range availableApprox. 900–1070 L/minApprox. 1070–1290 L/min30°C / 35°C reference or project-confirmedShell-and-tube evaporator or project-reviewed exchangerExternal pump station and buffer tank by projectPLC, HMI, Modbus, alarm output optionalExport voltage and frequency availableRequires engineering review of heat load, cooling tower, piping, transport, and installation.Central cooling system design, multiple loops, redundancy, special control.
Project-specific100+ HPReviewed according to heat load and operating scheduleCustom compressor and refrigeration configurationProject-definedCalculated by heat load and ΔTMatched to condenser and cooling tower designConfirmed by site condenser water conditionProject-reviewed exchangerExternal pump station, dual pump, or central systemProject-defined controller and communicationExport voltage and frequency availableFor large industrial cooling systems requiring project-level engineering.Shell-and-tube evaporator, stainless heat exchanger, dual pump, PLC, Modbus, skid-mounted structure.

Special Water Cooled Chiller Datasheet Configuration Options

Configuration items commonly reviewed before final datasheet
Configuration TypeTypical UseKey Datasheet ItemsSelection Notes
Stainless Steel Water Cooled ChillerFood, chemical, corrosion-sensitive or clean process coolingStainless steel tank, stainless steel piping, plate heat exchanger, water quality requirementConfirm fluid, corrosion risk, cleaning requirement, and installation environment.
Central Water Cooled Chiller SystemFactory production line or multi-equipment coolingTotal heat load, pump flow, main pipe pressure, buffer tank, control systemConfirm total connected equipment, simultaneity factor, and pressure loss.
High Temperature Process CoolingProcess water cooling where outlet temperature is higher than standard chilled waterCooling capacity at required temperature, condenser water condition, control rangeHigher outlet temperature may increase available cooling capacity.
Low Temperature Water Cooled ChillerSpecial process cooling below standard rangeGlycol ratio, evaporator protection, refrigerant, compressor, anti-freeze controlCapacity must be recalculated at low outlet temperature.
How to Read

How to Read the Datasheet Tables

Capacity Depends on Temperature

Cooling capacity is affected by chilled water outlet temperature and condenser water inlet temperature.

Chilled Water Flow

Chilled water flow rate is usually calculated according to heat load and temperature difference.

Condenser Water Flow

Condenser water flow rate should match cooling tower and condenser design.

Pump Pressure

Pump pressure should be selected according to pipe distance, height difference, valves, filters, and equipment pressure loss.

Voltage and Frequency

Voltage and frequency must be confirmed before quotation and final electrical configuration.

Final Datasheet

Final datasheet should be confirmed after reviewing the real application and operating conditions.

Technical Parameters

Technical Parameters Explained

ParameterWhat It MeansSelection Note
Cooling CapacityRequired heat removal capacityConfirm based on real process heat load and operating temperature.
Chilled Water Outlet TemperatureTarget water temperature supplied to the processLower outlet temperature may reduce available cooling capacity.
Chilled Water Flow RateWater circulation volume through the processMatch flow rate with heat load, ΔT, and equipment requirement.
Condenser Water Flow RateWater flow through the water cooled condenserMust match cooling tower, condenser pressure, and heat rejection requirement.
Condenser Water Inlet TemperatureCooling water temperature entering the condenserHigher condenser water temperature may reduce efficiency and cooling capacity.
Pump PressureAvailable pressure for chilled water circulationCheck pipe distance, height, valves, filters, and equipment resistance.
Evaporator TypeHeat exchanger between chilled water and refrigerantPlate heat exchanger is compact; shell-and-tube is suitable for larger or special systems.
Power SupplyVoltage, phase, and frequencyConfirm according to country and site electrical system.
Selection Notes

Water Cooled Chiller Selection Notes

Cooling Tower Required

Water cooled chillers require condenser water from a cooling tower or central condenser water circuit.

Better for Larger Capacity

Water cooled systems are often preferred for larger heat loads and continuous industrial operation.

Condenser Water Condition Matters

The datasheet should confirm condenser water inlet and outlet temperature, water quality, and flow rate.

Indoor Installation Advantage

Water cooled chillers are commonly installed indoors, with heat rejected through condenser water.

Maintenance Consideration

Cooling tower, condenser cleaning, water treatment, and pipe system maintenance should be considered.

Custom System Options

Pump, tank, evaporator, condenser, control panel, communication, and voltage can be customized.

Request Data

Information Needed Before Requesting a Water Cooled Chiller Datasheet

Required cooling capacity or process heat load
Chilled water inlet and outlet temperature
Chilled water flow rate requirement
Condenser water inlet and outlet temperature
Cooling tower or condenser water condition
Fluid type
Pump flow and pressure requirement
Voltage / phase / frequency
Ambient and installation environment
Application equipment type
Continuous or intermittent operation
Special material or control requirement
FAQ

Water Cooled Chiller Datasheet FAQ

What information is included in a water cooled chiller datasheet?

A water cooled chiller datasheet usually includes cooling capacity, compressor power, chilled water flow rate, condenser water flow rate, temperature range, evaporator type, condenser type, refrigerant, voltage, pump options, and installation notes.

Are the cooling capacity values in the table final selection data?

No. The values are reference data for initial comparison. Final capacity should be checked according to heat load, chilled water outlet temperature, condenser water inlet temperature, and operating conditions.

Why does condenser water temperature affect chiller capacity?

Higher condenser water inlet temperature increases condensing pressure and may reduce cooling capacity and efficiency. The datasheet should always confirm the condenser water condition.

Does a water cooled chiller require a cooling tower?

In most cases, yes. A water cooled chiller requires condenser water from a cooling tower or central condenser water system to reject heat.

How should I compare chilled water flow rate?

Chilled water flow rate is related to heat load and temperature difference. The final flow rate should match the process equipment requirement and pipe system design.

Can condenser water flow rate be customized?

Yes. Condenser water flow rate can be reviewed according to condenser design, cooling tower condition, and project heat rejection requirement.

Can APT provide stainless steel water cooled chillers?

Yes. APT can provide stainless steel tank, stainless steel piping, and suitable heat exchanger options for food, chemical, corrosion-sensitive, or clean process applications.

What is the difference between air cooled and water cooled chiller datasheets?

Air cooled chiller datasheets focus on condenser airflow and ambient temperature, while water cooled chiller datasheets must also include condenser water inlet temperature, condenser water flow rate, and cooling tower conditions.

Can pump flow and pressure be customized?

Yes. Pump flow and pressure can be adjusted according to pipe distance, pressure loss, equipment resistance, and required circulation condition.

Can APT prepare a project-specific water cooled chiller datasheet?

Yes. APT can prepare a project-specific datasheet after reviewing cooling capacity, target temperature, condenser water condition, fluid, pump requirement, voltage, application, and installation conditions.

Next Step

Request Water Cooled Industrial Chiller Datasheets

Send your cooling capacity, target chilled water temperature, condenser water condition, flow requirement, pump pressure, voltage, process fluid, and application details. APT can prepare a project-specific water cooled chiller datasheet after engineering review.

Scroll to Top
Chat on WhatsApp