Export Voltage Reference

Industrial Chiller Export Voltage Configuration Reference

Reference technical data for export industrial chiller voltage, phase, frequency, electrical components, compressor compatibility, control voltage, and country-specific power supply requirements.

Industrial chillers for export projects must be configured according to the site power supply. Voltage, phase, frequency, compressor type, pump motor, condenser fan, control transformer, electrical protection, and wiring standards should be reviewed before quotation and production.

Voltage / phase / frequency confirmation before production
Compressor, pump, fan, controller, and protection matching
Transformer and control voltage review when required
Country reference plus actual site power confirmation
Quick Answer

Quick Answer: Why Voltage Configuration Matters for Export Chillers

An industrial chiller export voltage configuration defines how the chiller electrical system is matched to the customer's local power supply. It usually includes voltage, phase, frequency, compressor compatibility, pump and fan motor selection, control voltage, protection devices, wiring design, and optional transformer configuration.

Confirm before quotation

Voltage, phase, and frequency should be confirmed before final chiller quotation and production.

Components must match

Compressors, pumps, fans, contactors, controllers, and protection devices must match the selected power supply.

Country reference is not enough

Country voltage tables are useful, but the final configuration should be confirmed according to the actual project site.

Configuration Matrix

Industrial Chiller Export Voltage Configuration Matrix

Use this matrix as a preliminary reference before confirming the final industrial chiller electrical configuration, compressor compatibility, motor selection, and control panel design.

Voltage Configuration Typical Use Key Datasheet Items Selection Notes
220V / 1 Phase / 50Hz or 60Hz Small compact chillers, laboratory chillers, small equipment cooling Compressor power limit, pump power, plug or terminal connection, current rating Usually suitable for small-capacity chillers only. Confirm current limit and site wiring.
220V / 3 Phase / 50Hz or 60Hz Some regional industrial power systems and compact three-phase chillers Compressor compatibility, motor selection, control transformer, protection devices Must confirm whether the site power is truly three-phase 220V.
380V / 3 Phase / 50Hz Common industrial power supply in China and many export projects Compressor, pump, fan, controller, electrical panel configuration Often used as a standard industrial chiller configuration, but export projects still need site confirmation.
400V / 3 Phase / 50Hz Many European and international industrial installations Compressor rating, motor rating, control voltage, electrical protection Check whether 380V components can operate within acceptable voltage tolerance or require 400V-specific selection.
415V / 3 Phase / 50Hz UK, Australia, Middle East, Southeast Asia, and some industrial sites Compressor compatibility, pump motor, fan motor, protection range Confirm voltage tolerance and local electrical requirement before production.
460V / 3 Phase / 60Hz United States, Canada, and some North American industrial sites 60Hz compressor, pump, fan, electrical components, control transformer 60Hz component selection is required. Do not simply use 50Hz configuration.
480V / 3 Phase / 60Hz North American industrial facilities Electrical panel rating, transformer option, motor compatibility, protection devices Confirm whether site supply is 460V or 480V and whether voltage tolerance is acceptable.
Special Voltage Project-specific export markets, OEM equipment, ships, offshore, special factories Voltage, phase, frequency, neutral requirement, grounding system, transformer Project review is required before quotation and production.
Country Reference

Common Industrial Voltage Reference by Market

This market reference helps prepare early discussion, but final export industrial chiller voltage configuration must be confirmed by the actual site power supply and local electrical requirement.

Market / Region Common Industrial Voltage Frequency Notes for Chiller Selection
United States208V / 230V / 460V / 480V, 3 Phase60HzConfirm site voltage carefully. 60Hz compressors, pumps, fans, and electrical parts may be required.
Canada208V / 230V / 460V / 575V, 3 Phase60Hz575V may require special component review or transformer solution.
European Union400V / 3 Phase50HzCheck CE-related electrical requirements if needed by the project.
United Kingdom400V / 415V / 3 Phase50HzConfirm site voltage and protection requirement before production.
Australia400V / 415V / 3 Phase50Hz415V industrial supply is common. Component tolerance should be reviewed.
Middle East380V / 400V / 415V / 3 Phase50HzHigh ambient temperature may also affect chiller selection.
Southeast Asia380V / 400V / 415V / 3 Phase50HzVoltage varies by country and factory. Confirm site electrical data.
India415V / 3 Phase50HzConfirm voltage stability, ambient condition, and protection requirement.
China380V / 3 Phase50HzCommon standard for many industrial chiller configurations.
Japan200V / 3 Phase50Hz or 60HzFrequency depends on region. Special design may be required.
South Korea380V / 440V / 3 Phase60Hz60Hz component selection should be reviewed.
Latin America220V / 380V / 440V / 460V, 3 Phase50Hz or 60HzCountry and site power supply must be confirmed case by case.
Africa380V / 400V / 415V, 3 Phase50HzVoltage stability and site conditions should be reviewed.
This table is for preliminary reference only. Final chiller voltage configuration must be confirmed according to the actual project site power supply, local electrical code, and component availability.
Datasheet Tables

Reference Datasheet Tables for Export Electrical Configuration

These compact tables organize the main electrical fields that should be reviewed before APT confirms export industrial chiller voltage configuration.

Main Power Supply Datasheet Reference

ItemReference DataProject Review Notes
Voltage220V / 380V / 400V / 415V / 460V / 480V / project-definedConfirm actual site power supply.
PhaseSingle phase or three phaseMatch compressor and motor selection.
Frequency50Hz or 60HzFrequency affects component selection.
Power ToleranceReviewed by component ratingCheck site condition and voltage stability.
Neutral LineRequired or not requiredDepends on control system design.
GroundingSite grounding requirementConfirm local electrical requirement.

Compressor Voltage Compatibility Reference

ItemReference DataProject Review Notes
Compressor TypeScroll, semi-hermetic, screw, or project-selected compressorSelected according to cooling capacity.
VoltageMatched according to site power supplyConfirm before production.
Frequency50Hz or 60Hz compressor selection may differDo not mix unmatched component configuration.
Starting MethodDirect start, star-delta, soft start, or VFD optionDepends on model and site requirement.
ProtectionOverload, phase protection, high/low pressure protectionProtection setting must match final panel.

Pump and Fan Motor Voltage Reference

ItemReference DataProject Review Notes
Pump MotorMatched by voltage, phase, frequency, flow, and pressureReview pump curve and site power.
Condenser FanSelected by voltage, frequency, airflow, and ambient conditionImportant for air cooled chillers.
Motor ProtectionOverload, phase protection, thermal protection if requiredMatch panel protection settings.
Special PumpHigh pressure or stainless steel pumpSeparate voltage confirmation may be needed.
Selection NoteMotor current and protection settingsMatch the final electrical configuration.

Control Panel and Transformer Reference

ItemReference DataProject Review Notes
Control Voltage24V / 110V / 220V / project-reviewedConfirm service and local preference.
TransformerUsed when control voltage differs from main supplyReview load and panel space.
ControllerTemperature controller, PLC, or custom control systemMatch project control logic.
Protection DevicesBreaker, contactor, overload relay, phase sequence protectorSelected according to final electrical design.
WiringTerminal connection and wiring diagramPrepared according to final design.
Ordering Review

How to Confirm Voltage Before Ordering an Export Chiller

1

Confirm Site Voltage

Check the actual voltage available at the installation site, not only the country standard.

2

Confirm Phase

Confirm whether the site supply is single phase or three phase.

3

Confirm Frequency

Confirm whether the project requires 50Hz or 60Hz electrical components.

4

Confirm Voltage Stability

For sites with unstable power supply, additional protection or transformer options may be reviewed.

5

Confirm Local Electrical Requirement

Some projects may require specific electrical standards, certification, cable entry, or protection devices.

6

Confirm Before Production

Voltage configuration should be finalized before purchasing compressors, pumps, fans, and electrical components.

Export Options

Common Export Voltage Options for Industrial Chillers

Option Purpose Information Required
Standard 380V / 3 Phase / 50HzCommon industrial chiller configuration for many projectsConfirm whether the site accepts 380V 50Hz power supply.
400V / 415V / 3 Phase / 50HzSupport many European, UK, Australian, Middle East, and international installationsConfirm site voltage, tolerance, and local electrical requirement.
460V / 480V / 3 Phase / 60HzSupport North American industrial power systemsConfirm exact voltage, frequency, compressor availability, and protection requirement.
220V / 1 PhaseSupport small chillers or compact equipment coolingConfirm current limit, cooling capacity, plug or terminal requirement.
220V / 3 PhaseSupport specific regional industrial power systemsConfirm three-phase supply and component compatibility.
Built-in TransformerAdapt control voltage or special electrical requirementMain voltage, control voltage, load, panel space, maintenance preference.
Remote Control PanelSupport special installation or hazardous area requirementCable length, control signal, installation location, environment.
Special Electrical DesignSupport OEM, marine, offshore, explosion-proof, or special project requirementsElectrical specification, drawings, standard requirement, site condition.
Quotation Data

Information Needed Before Requesting an Export Voltage Configuration

Send the country, site voltage, phase, frequency, and application details to APT for export industrial chiller voltage configuration review.

  • Installation country
  • Actual site voltage
  • Phase: single phase or three phase
  • Frequency: 50Hz or 60Hz
  • Whether neutral line is available
  • Site power stability information if available
  • Required cooling capacity
  • Chiller type: air cooled or water cooled
  • Pump flow and pressure requirement
  • Application equipment type
  • Indoor or outdoor installation
  • Ambient temperature
  • Required control voltage if specified
  • Local electrical standard or certification requirement
  • Special protection requirement
  • Photos of existing electrical panel if replacing an old chiller
FAQ

Industrial Chiller Export Voltage FAQ

Why does voltage need to be confirmed before ordering an industrial chiller?

Voltage must be confirmed because compressors, pumps, fans, controllers, contactors, protection devices, and wiring design must match the actual site power supply.

Can an industrial chiller be supplied with 380V 50Hz?

Yes. 380V 3 phase 50Hz is a common industrial chiller configuration, but the final voltage should still be confirmed according to the project site.

Can APT provide 400V or 415V industrial chillers?

Yes. APT can review 400V or 415V 3 phase 50Hz configurations for export projects after confirming the site electrical requirements.

Can APT provide 460V or 480V 60Hz chillers?

Yes. APT can review 460V or 480V 3 phase 60Hz chiller configurations, including compressor, pump, fan, and electrical component compatibility.

Is country voltage information enough for chiller production?

No. Country voltage information is only a reference. The actual site voltage, phase, frequency, and local electrical requirements should be confirmed before production.

Does frequency affect chiller selection?

Yes. 50Hz and 60Hz systems may require different compressor, pump, fan, and protection selections. The operating performance should be reviewed according to frequency.

Can a transformer be used for an export chiller?

Yes. A transformer may be reviewed when control voltage or site voltage adaptation is required, but it should be selected according to load, safety, panel space, and maintenance requirements.

Can small chillers use single phase power?

Some small chillers can use single phase power, but cooling capacity, compressor current, and site wiring limits must be checked carefully.

What electrical information is needed before quotation?

APT usually needs the installation country, site voltage, phase, frequency, neutral line condition, cooling capacity, application, and any local electrical standard or protection requirement.

Can APT prepare a project-specific export voltage datasheet?

Yes. APT can prepare a project-specific industrial chiller voltage configuration datasheet after reviewing the project power supply and application requirements.

Engineering Review

Confirm Export Voltage Configuration Before Chiller Production